电气部分系泊及航行试验大纲1

MOORING TEST General After installing all electric equipment, the mooring test and sea Trial test may be carried out as per the test schedule. And the test Schedule should be complied with “UMS on board test schedule” of LR’s. Before testing each major item, owner and surveyor should be attendant. If necessary, the designer of SDARI may be attendant. And LR’s or maker’s certificate of major equipment should be provided. 1.3 In general, every test shall be carried out to confirm the sufficient functions and operations of electric equipment and also to confirm the protection, safety devices after installation on board. 1.4 The test method of electric equipment for machinery and deck auxilia- ries shall be conducted in accordance with mooring test program of machinery part and procedure of sea trial. In general, the insulation resistance shall be no less than 1 megohm for circuits with voltage above 50v and 0.3 megohm for those below 50v, Insulation resistance for the circuits with voltage above 50v shall be measured with a DC 500v megger and for circuits with voltage below 50v shall be measured with an ohmmeter. The detail records of major electric equipment tests will be made. And The test results shall be submitted to owner after finishing the tests. Main generator Particulars of main generator Output 750kVA (600kW) Voltage 450V Current 962A Phase 3 phase Frequency 60HZ Revolution 900rpm Power factor 0.8(lagging) Rating continuous Insulation class F Protection IP23 Type horizontal, synchronization Automatic alarm and safety stop device of main diesel generator plant shall be submitted for acceptance before following test (see method of automation equipment test in engine room). Insulation resistance test Before and after heat run test, the insulation resistance between the following item shall be measured with D.C. 500V megger, value of insulation resistance shall not be less than 1MΩ.

文档评论(0)

zyzsab + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档