- 1、本文档共11页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Removal of albumin on the cerebrospinal fluid of two-dimensional gel electrophoresis
PAGE \* MERGEFORMAT 11
Removal of albumin on the cerebrospinal fluid of two-dimensional gel electrophoresis
Of: Zhou Yue, peace, Qu Jianqiang, Wang Li
[Abstract] Objective To investigate the removal of albumin on the cerebrospinal fluid of two-dimensional gel electrophoresis. Methods HiTrapTM Blue Column, specific removal of albumin in cerebrospinal fluid, and then the removal of albumin in cerebrospinal fluid samples before and after the two-dimensional gel electrophoresis research, comparative analysis of the results. results are not clear albumin dimensional gel electrophoresis of cerebrospinal fluid samples can be detected about 200 protein spots, and after removal of cerebrospinal fluid samples of albumin dimensional gel electrophoresis detected only about 30 protein spots. a large number of other proteins associated with albumin at the same time information is lost, the remaining information is difficult to fully reflect the cerebrospinal fluid proteins proteomics maps. Conclusion albumin may result in removal of the corresponding proteins of other loss that can affect the cerebrospinal fluid of two-dimensional gel electrophoresis findings.
[Keywords:] cerebrospinal fluid; albumin; two-dimensional gel electrophoresis
ABSTRACT: Objective To explore the effects of albumen depletion on cerebrospinal fluid (CSF) two dimensional gel electrophoresis (2 DE) research. Methods Albumen was specially removed from CSF by HiTrapTM Blue. Then, CSF samples with and without albumen were compared by 2 DE . Results About 200 spots in normal CSF and 30 spots in CSF without albumen were found by 2 DE. Lots of proteins were lost in CSF after albumen depletion. It was difficult for the vestigial proteins 2 DE map to present the protein composition of CSF . Conclusion Lots of proteins are lost when albumen is removed from CSF, which will affect CSF 2 DE analysis results.
KEY WORDS: cerebrospinal fluid (CSF); albumen; two dimensional gel electrophoresis
Centr
您可能关注的文档
- Reflections on a decade of marketing.doc
- Reflections from the treatment of urinary tract infections a number of issues of clinical medicine.doc
- Reflections on Korea-Japan World Cup Media Marketing.doc
- Reflections on China's retail industry.doc
- Reflections on Marketing- Kotler in his way for brand positioning era curtain.doc
- Reflection on the brain combined with conventional treatment for hemiplegia cerebral infarction drug treatment and nursing observation.doc
- Refined safflower chitosan flocculation process of water extract.doc
- Reflections on medicine and health products business strategy of the status quo.doc
- Reflections on Nursing Management Strategy.doc
- Reflections on pharmacy development.doc
- 中国国家标准 GB 42125.11-2025测量、控制和实验室用电气设备的安全要求 第11部分:用于处理医用材料的灭菌器和清洗消毒器的特殊要求.pdf
- 《GB 42125.11-2025测量、控制和实验室用电气设备的安全要求 第11部分:用于处理医用材料的灭菌器和清洗消毒器的特殊要求》.pdf
- 《GB/T 15237-2025术语工作及术语科学 词汇》.pdf
- GB/T 15237-2025术语工作及术语科学 词汇.pdf
- GB/T 22454-2025企业建模与体系结构 企业建模构件.pdf
- 中国国家标准 GB/T 15237-2025术语工作及术语科学 词汇.pdf
- 中国国家标准 GB/T 22454-2025企业建模与体系结构 企业建模构件.pdf
- 《GB/T 22454-2025企业建模与体系结构 企业建模构件》.pdf
- 中国国家标准 GB/T 18910.64-2025液晶显示器件 第6-4部分:测试方法 带动态背光的液晶显示模块.pdf
- 《GB/T 18910.64-2025液晶显示器件 第6-4部分:测试方法 带动态背光的液晶显示模块》.pdf
文档评论(0)