Effects of Beam Startup Characteristics on Dose Delivery Accuracy at Low Monitor Units in Step-and-Shoot Intensity Modulated Radiation Therapy
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2013, 2, 1-5
Published Online February 2013 (/journal/ijmpcero)
/10.4236/ijmpcero.2013.21001
Effects of Beam Startup Characteristics on Dose Delivery
Accuracy at Low Monitor Units in Step-and-Shoot
Intensity Modulated Radiation Therapy
Kazunori Fujimoto , Kunihiko Tateoka , Yuji Yaegashi , Katsumi Shima , Junji Suzuki ,
1,2 1,3 1 1 1
1 1 1 1
Yuichi Saito , Akihiro Nakata , Takuya Nakazawa , Tadanori Abe , Masaki Yano ,
1
3 3 3 2 1,3
Masanori Someya
, Kensei Nakata
, Masakazu Hori
, Masato Hareyama
, Koichi Sakata
1
Department of Medical Physics, Graduate School of Medicine, Sapporo Medical University, Sapporo, Japan
Radiation Therapy Research Institute, Social Medical Corporation Teishinkai, Sapporo, Japan
2
3
Department of Radiology, Sapporo Medical University, Sapporo, Japan
Email: tateoka@sapmed.ac.jp
Received September 11, 2012; revised October 15, 2012; accepted October 23, 2012
ABSTRACT
Intensity modulated radiation therapy (IMRT) is a highly accurate technique that is usually implemented in either dy-
namic or step-and-shoot fashion with many segments each having low monitor units (MUs). The present study evalu-
ated the effects of beam startup characteristics on the dose delivery accuracy for each segment at low MUs for
step-and-shoot IMRT with an Elekta Precise accelerator at the highest dose rates. We used a two-dimensional semi-
conductor detector for the dos
您可能关注的文档
- Effects of acute and repeated immobilization stress on oxygen consumption of the isolated interstitial rats' testes cells.doc
- Effects of Afforestation with Pines on Collembola Diversity in the Limestone hills of Szárhalom (West Hungary).doc
- Effects of alternative protein sources on rumen microbes and productivity of dairy cows.doc
- Effects of Antimicrobial Peptide Revealed by Simulations Translocation, Pore Formation, Membrane Corrugation and Euler Buckling.doc
- Effective Geothermal Utilisation close to the surface by the TT-Geothermal Radial Drilling (GRD-)Method.doc
- Effects of Abandoned Arsenic Mine on Water Resources Pollution in North West of Iran.doc
- Effects of Building a Highway and Wildlife Crossings in a Red Deer (Cervus elaphus) Habitat in Hungary.doc
- Effects of carcass weight on quality of major carcass cuts, their composition, and meat in Lithuanian slaughter pig population.doc
- Effects of change of use of land on an aquifer in a tectonically active region.doc
- Effects of Cowpea mottle virus and Cucumber mosaic virus on six Soybean (Glycine max L.) cultivars.doc
- Effects of climate model radiation, humidity and wind estimates on hydrological simulations.doc
- EFFECTS OF DEPOSITION PARAME TERS AND OXYGEN ADDITION ON PROPERTIES OF SPUTTERED INDIUM TIN OXIDE FILMS.doc
- Effects of dietary CoQ10 and α-lipoic acid on CoQ10 levels in plasma and tissues of eggs laying hens.doc
- Effects of different doses of dexamethasone plus flunixin meglumine on survival rate in lethal endotoxemia.doc
- Effects of different inputs of organic matter on the response of plant production to a soil water stress in Sahelian region.doc
文档评论(0)