Time Delay for Aerial Ammonia Concentration Measurements in Livestock Buildings 英文参考文献
Sensors 2010, 10, 4634-4642;10.3390/s100504634
OPEN ACCESS
sensors
ISSN 1424-8220
/journal/sensors
Article
Time Delay for Aerial Ammonia Concentration Measurements
in Livestock Buildings
Hans Benny Rom * and Guo-Qiang Zhang
Department of Biosystems Engineering, University of Aarhus, Faculty of Agricultural Sciences,
Blichers Alle 20, DK-8830 Tjele, Denmark; E-Mail: GuoQiang.Zhang@agrsci.dk
* Author to whom correspondence should be addressed; E-Mail: hansb.rom@agrsci.dk;
Tel.: +45-89-99-18-72; Fax: +45-89-99-16-19.
Received: 1 March 2010; in revised form: 29 March 2010 / Accepted: 15 April 2010 /
Published: 4 May 2010
Abstract: Correct measurements of ammonia concentration in air still present considerable
challenges. The high water solubility and polarity can cause it to adsorb on surfaces in the
entire sampling system, including sampling lines, filters, valves, pumps and instruments,
causing substantial measuring errors and time delays. To estimate time delay
characteristics of a Photo Acoustic Multi Gas Monitor 1312 and a Multi Point Sampler
continuous measurement of aerial ammonia concentrations at different levels was
performed. In order to obtain reproducible data, a wind tunnel was used to generate
selected concentrations inside and a background concentration representing the air inlet of
the tunnel. Four different concentration levels (0.8 ppm, 6.2 ppm, 9.7 ppm and 13.7 ppm)
were used in the experiments, with an additional outdoor concentration level as
background. The results indicated a substantial time delay when switching between the
measuring positions with high and low concentration and vice versa. These properties may
course serious errors for estimation of e.g. gas emissions whenever more than one
measuring channel is applied. To reduce the measurement errors, some suggestions
regarding design of the measurement setup
您可能关注的文档
- Thoracic trident pigmentation in Drosophila melanogaster Differentiation of geographical populations 英文参考文献.doc
- THREAT helps to identify epistaxis patients requiring blood transfusions 英文参考文献.doc
- Three dimensional evaluation of posture in standing with the PosturePrint an intra- and inter-examiner reliability study 英文参考文献.doc
- Three Cavity Tunable MEMS Fabry Perot Interferometer 英文参考文献.doc
- Three lateral osteotomy designs for bilateral sagittal split osteotomy biomechanical evaluation with three-dimensional finite element analysis 英文参考文献.doc
- Three New Myrsinol Diterpenes from Euphorbia prolifera and Their Neuroprotective Activities 英文参考文献.doc
- Three New Caffeoyl Glycosides from the Roots of Picrorhiza Scrophulariiflora 英文参考文献.doc
- Three dimensional structure directs T-cell epitope dominance associated with allergy 英文参考文献.doc
- Three versions of Perceived Stress Scale validation in a sample of Chinese cardiac patients who smoke 英文参考文献.doc
- Three New Oblongolides from Phomopsis sp. XZ-01, an Endophytic Fungus from Camptotheca acuminate 英文参考文献.doc
文档评论(0)