无机房故障(国外英文资料)

无机房故障(国外英文资料) The failure code of mitsubishis engine room elevator E0 is no exception The E1 velocity is unusually low When E2 is too fast, check out Check out E3 in reverse The E4 AST is checked out when the AST is abnormal The E5 inverter is checked out by current The E6 rectifier checks out when it overvoltage An E7 rectifier is detected when the voltage is low Check out the E8 # LB coil failure Check out the E9 # 5 coil failure The EA force contact ON/OFF is checked out The eb-box is a direct transmission of an abnormal signal EC is a direct transmission of the signal anomaly ED system exception EE drivers cant start again EF control no longer starts the mitsubishi ELENESSA elevator failure query table Mitsubishi elevator ELENESSA called electronic board outside the top floor, there are two switches and MON1 MON0, just rotate the two switch to a different location, through the display of the alphabet, in contrast to the corresponding English description, can understand the elevator failure positions and failure time and the number of times. MON1 goes to zero, and turns the MON0 switch to zero, and the result is as follows: Display result - E0 no failure - - - - - - - E1 - - - - - - - - - - - -- -e2 is too fast to check out swa-tgbh. The E3 reversals are the detection of sw-tgbr. When the E4AST is abnormal, the swear-ast is detected. The ss-locfo is detected by the E5 inverter. - - the E6 rectifier checks out the ss-covh. The ss-lvlt was detected when the voltage was low. - - the E8LB coil failed to detect the SW - CFLB. - - - - - - - - - - E95 - - - - - - - - - - - - - - - - - - the EA force contact ON/OFF to check out SW - CFBK The barb is a direct transmission of the abnormal st-stsce. The exception of the EC and the direct signal transmission is the st-stshe. The ED system anomaly st-syer The EE driver is not able to start the sd-dnrs. -ef control is not able to start sw-nrs 0. Im going to change MON1, so Im going to rotate MON0 to 1. Display the position of

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档