造成ro反渗透膜使用寿命减短的原因(The cause of RO reverse osmosis membrane shortens the service life).docVIP

造成ro反渗透膜使用寿命减短的原因(The cause of RO reverse osmosis membrane shortens the service life).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
造成ro反渗透膜使用寿命减短的原因(The cause of RO reverse osmosis membrane shortens the service life)

造成ro反渗透膜使用寿命减短的原因(The cause of RO reverse osmosis membrane shortens the service life) The cause of RO reverse osmosis membrane shortens the service life First, the cause of RO life shortening: 1 reverse osmosis equipment damage caused by improper operation of membrane performance 1.1 reverse osmosis equipment in residual gas running under high pressure, the formation of air hammer will damage the Dow reverse osmosis membrane There are two things happen often: A equipment, emptied, re run, no exhaust gas quickly boost operation. Should be 2 ~ 4bar under the pressure of the remaining air is exhausted, and then gradually boost operation. B, joint between pretreatment equipment and high-pressure pump seal is not good or Water Leakage (especially when the pipeline Water Leakage microstrainer and later) when pretreated water is enough, such as microfiltration clogging, sealed in a bad place because the vacuum can be sucked in air. Should be cleaned or replaced microstrainer, guarantee the pipeline leakage. In short, there should be no bubble in the flow meter under the condition of step operation, during operation should gradually reduce the bubble check reason. Methods 1.2 reverse osmosis equipment shutdown is not correct A, shutdown of rapid decompression without a thorough washing. The concentration of inorganic salt membraneconcentrated water side of the above water, fouling and membrane pollution. B, pretreatment of washing water adding chemical reagent. Because of containing chemical reagents in water equipment during outage may cause membrane fouling. Reverse osmosis equipment in preparation for the shutdown, should stop adding chemical reagent, step-down to about 3bar with good water washing pretreatment 10min, TDS and TDS concentrated water until the water is very close now. 1.3 reverse osmosis equipment disinfection and maintenance lead to microbial contamination This is a composite polyamide membrane are common problems in the use of chlorine resistant polyamid

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档