造成ro反渗透膜使用寿命减短的原因(The cause of RO reverse osmosis membrane shortens the service life).docVIP
- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
造成ro反渗透膜使用寿命减短的原因(The cause of RO reverse osmosis membrane shortens the service life)
造成ro反渗透膜使用寿命减短的原因(The cause of RO reverse osmosis membrane shortens the service life)
The cause of RO reverse osmosis membrane shortens the service life
First, the cause of RO life shortening:
1 reverse osmosis equipment damage caused by improper operation of membrane performance
1.1 reverse osmosis equipment in residual gas running under high pressure, the formation of air hammer will damage the Dow reverse osmosis membrane
There are two things happen often:
A equipment, emptied, re run, no exhaust gas quickly boost operation. Should be 2 ~ 4bar under the pressure of the remaining air is exhausted, and then gradually boost operation.
B, joint between pretreatment equipment and high-pressure pump seal is not good or Water Leakage (especially when the pipeline Water Leakage microstrainer and later) when pretreated water is enough, such as microfiltration clogging, sealed in a bad place because the vacuum can be sucked in air. Should be cleaned or replaced microstrainer, guarantee the pipeline leakage. In short, there should be no bubble in the flow meter under the condition of step operation, during operation should gradually reduce the bubble check reason.
Methods 1.2 reverse osmosis equipment shutdown is not correct
A, shutdown of rapid decompression without a thorough washing. The concentration of inorganic salt membraneconcentrated water side of the above water, fouling and membrane pollution.
B, pretreatment of washing water adding chemical reagent. Because of containing chemical reagents in water equipment during outage may cause membrane fouling.
Reverse osmosis equipment in preparation for the shutdown, should stop adding chemical reagent, step-down to about 3bar with good water washing pretreatment 10min, TDS and TDS concentrated water until the water is very close now.
1.3 reverse osmosis equipment disinfection and maintenance lead to microbial contamination
This is a composite polyamide membrane are common problems in the use of chlorine resistant polyamid
您可能关注的文档
- 英语课堂导入等过程(English class introduction and so on).doc
- 英语附加疑问句特例(A special case of English tag questions).doc
- 英语词汇词根t(English word root t).doc
- 苹果树的钙营养及补钙技术综述(A review of calcium nutrition and calcium supplementation in apple trees).doc
- 苹果电脑公司的swot分析(SWOT analysis of Apple Com puter Inc).doc
- 苏越(Su).doc
- 茶文化与宗教发展的内在关系(The inner relationship between tea culture and religious development).doc
- 茜之塔(Crassula corymbulosa).doc
- 草图大师快捷键4(Sketch master shortcut key 4).doc
- 草坪整理资料(Lawn data).doc
- 造纸化学品(Paper chemicals).doc
- 道书十二种-神室八法(There are twelve kinds of Taoist books - eight divine chambers).doc
- 道吾山导游词(Tour guide).doc
- 造价员考试《土建工程》重点知识辅导(Cost staff examination civil engineering key knowledge guidance).doc
- 道岔论文(Turnout paper).doc
- 道路二灰碎石路拌法施工(Road two ash macadam mixing method construction).doc
- 道路施工(Road Construction).doc
- 通信名词解释(Explanation of communication terms).doc
- 造价考试复习资料(Cost examination review material).doc
- 道路试验段(Road test section).doc
文档评论(0)