盐雾试验箱的操作应注意以下操作要素(The following elements shall be noted in the operation of the salt mist test chamber) The operation of the salt mist test chamber shall be observed in the salt mist test chamber: Sodium Chloride Solution 5 best day percent concentration calibration concentration at a time After pH 6.5 6.5~7.2 collection, determine the pH value in the test Compressed air pressure (kgf/cm2)...... 1 + 0.01 shall not be interrupted continuously /h (ml/80cm2)...... 1.0~2.0 should collect at least 16 hours for average Pressure barrel temperature (DEG C)...... 47 + 1 Salt bucket temperature (DEG C)...... 35 + 1 Test room temperature (DEG C)...... 35 + 1 Test room relative humidity...... 85%. Other humidity requirements shall be agreed between the seller and the buyer. The test time shall be from the beginning of the spray to the end of the continuous time, or to the agreement between the seller and the buyer. Preparation of test solution: dissolve reagent grade sodium chloride (1) in distilled water (or total dissolved solids less than 200 ppm), a test solution of concentration of 5 + 1% was formulated (2). When the test solution is sprayed at 35 degrees centigrade, the pH value of the collected liquid should be 6.5~7.3 (3). Before spraying, the test solution can not contain suspended solids (4). The impurity of a: sodium chloride can not contain copper and nickel, sodium iodide content in solid should be less than 0.1%. Because of impurity May contain corrosion inhibitors, so the total content of impurities must be less than 0.3%. B: is measured at 33~35 degrees centigrade. The specific gravity of the test solution should be 1.0258~1.0402, and the specific gravity at the rate of 25 DEG C is 1.0292~1.0443. The concentration of this test solution can also be calibrated by silver nitrate titration or other methods. C: test is required to verify the supervision of liquid acid or dilute sodium hydroxide solution to adjust the pH value and the pH instrument or other reliable m

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档