平法梁、柱、板、墙的计算(Calculation of flat beam, column, plate and wall).doc

平法梁、柱、板、墙的计算(Calculation of flat beam, column, plate and wall)

平法梁、柱、板、墙的计算(Calculation of flat beam, column, plate and wall) Stirrup length = 2* (H-2*25+B-2*25) + (11.9*2+8) d Root count = 2* (encryption area length -50) / encryption spacing +1 + (non encryption area length / non encrypted spacing -1) Here, pay attention to the protective layer refers to the outer skin of the steel bar. Note: the scope of reinforcement area is determined by first class seismic max{2Hb, =500}; two stage seismic max{1.5Hb, =500} Flat method series (two) - column In the column of 03G101-1, there are many rules and regulations for column. In practical engineering, the calculation of column longitudinal reinforcement and stirrup is the most easily confused place in the calculation of column reinforcement. Here we will be combined with software in the column calculation of reinforced steel simple analysis. Name and number of plain column structure Two. Calculation of reinforcing bar in column (1) basic layer Foundation reinforcement Base bars = base thickness - protective layer + bend length + length of steel bar extending into the upper layer Hn/3 Where: Hn refers to the height of the second picture that column, H (high) -h (Liang Gao) Foundation stirrup The action of the stirrups in the foundation acts only as a stabilizing force, or it can be said to prevent the steel bar from being subjected to torsion during the casting. (two) interlayer; Longitudinal reinforcement KZ longitudinal reinforcement of the middle layer = storey height of the current layer extending above the ground + extending the height of the ground floor Of which: the middle layer extends out, the floor height is Max{500, the column long side size, Hn/6}, and this value can also be modified according to the actual situation in the calculation settings. When the middle column has variable cross section, it is necessary to determine whether the column reinforcement needs to be calculated according to the 44 page rule in the 03G101-1. Column Tie-Bar The number of stirrups in the mid

您可能关注的文档

文档评论(0)

1亿VIP精品文档

相关文档