  • 举报
Revisom 1 U.S. NUCLEAR REGULATORY COMMISSION July 1977 x REGULATORY GUIDE OFFICE OF STANDARDS DEVELOPMENT REGULATORY GUIDE 1.115 PROTECTION AGAINST LOW-TRAJECTORY TURBINE MISSILES A. INTRODUCTION • mal operation. Missiles resulting from destructive -overspeed -failures would be generated7-iftie General Design Criterion 4, Environmental and overspeed protection system malfunctions and the Missile Design Bases, of Appendix A, General turbine speed increases to a point at which the low Design Criteria for Nuclear Power Plants, to 10 pressure wheels or rotor will undergo ductile failure. CFR Part 50, Licensing of Production and Utiliza The kinetic energy of ejected missiles can be sufficient tion Facilities, requires, in part, that structures, to damage even substantial reinforced concrete slabs systems, and components important to safety be ap and panels. Thus turbine missiles have the potential propriately protected, against the effects of missiles for damaging safety-related structures, systems, and that might result from equipment failures. Failures components o