公众娱乐场所牌照之规定.docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
公众娱乐场所牌照之规定

公眾娛樂場所牌照之規定 Requirements for Places of Public Entertainment Licence (劇院) (Theatre) 隔火帳之規格 Specifications for Safety Curtain 1. 隔火帳之構造必須堅固。若因高度之限制而不能使用整幅之堅固隔火帳,可准予使用兩幅相交而閉不透之堅固隔火帳。 It shall be of robust and rigid construction. Where height limitations preclude the use of a full size rigid safety curtain, it is permissible to use a safety curtain comprising two rigid, overlapping sections with a smoke seal where the sections overlap. 2. 隔火帳必須以不燃之材料組成,能抵受佈景、道具、或墜落碎片之損毀、以及所具之堅?性足以抵禦因舞台區失火可能形成之氣壓,而不致變形脫離保持框;足以封住活動帳與固定結構之間,使不能透過;能抵受火焰,以便有充份時間撤離該大廈。不得使用捲動式隔火帳。標準之結構包括鋼框,而向舞台的一面用鋼薄片,及向觀眾席的一面則用金屬絲與不燃材料所織成之布構成。(對於以水壓軋成1/16吋(1.5875毫米)厚之鐵片代替不燃布作為向觀眾席的一面,本處可予以接受。)(“不燃材料”係指根據現行英國標準規格第四百七十六條第四部之規定試驗時被鑑定為不燃之材料。) The safety curtain shall consist of non-combustible materials, shall be able to withstand damage by scenery, properties or falling debris, and be of such strength and stiffness as to resist the pressure of air likely to be caused by fire in the stage area without such distortion as would cause its withdrawal from its retaining guides; shall provide adequate seal against the passage of smoke between the movable curtain and the fixed structure; and shall be able to withstand the effect of fire for a sufficient period to allow the complete evacuation of the building. The use of roller type safety curtains is not approved. A typical construction would consist of steel framework with steel sheeting on the stage side and wire woven non-combustible cloth on the auditorium side. (This Department would, however, be prepared to accept a covering of 1.6 mm thick hydraulically flattened sheet iron for the auditorium side of the curtain in lieu of the non-combustible cloth.) (‘Non-combustible material’ means material which is deemed to be non-combustible when tested in accordance with the provisions of the current edition of British Standard 476: Part 4.) 3. 儘管隔火帳的表面可能受火造成氣壓影響,隔火帳與其平衡重量之相對重量應在按動放鬆裝置後,能於30秒內將隔火帳暢順垂下,把舞台前部之空間完全遮住。 The relative weight of the curtain and its counter

文档评论(0)

ipbohn97 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档