兵团严寒地区村镇既有建筑节能改造技术分析-technical analysis on energy saving renovation of existing buildings in villages and towns in severe cold area of bingtuan.docxVIP
- 3
- 0
- 约4.46万字
- 约 64页
- 2018-06-28 发布于上海
- 举报
兵团严寒地区村镇既有建筑节能改造技术分析-technical analysis on energy saving renovation of existing buildings in villages and towns in severe cold area of bingtuan
AbstractTheimplementationofenergy-savingstandardswaslatedinseverecoldareainXinjiangCorps,thesurveyfoundtheruralhouseinsulationperformancewaspooranduncomfortablegeneral,andtheenergyconsumptionwashigher3~4timesthanthecurrentcityenergysavingresidential,Thehighenergyconsumptionofexistingbuildingswasdrawfurtherapartwiththenewconservationsociety,sotransformtheexistingbuildingswasrequired.Inaddition,theutilizationofsolarenergywasonthelowsideandintegrationofarchitectureandsolarenergyintegrationwaslack.Inthispaper,throughtheanalysisofthecoldareadefinitionandcorpscoldclimatefeatures,onthebasisoftheresearch,thevillageCorpscoldareaofexistingbuildingsisanalyzed,thevillageresidentbuildingheatingfacilitiesefficiencyislow,theheatingenergyishigh,thebuildingenvelopethermalperformanceispoor,theindoorthermalenvironmentcannotmeetthedemandofpeopleliving.Finally,throughtheindoorandoutdoortemperaturetestoftypicalbuildingresearcharea,someunderstandingofthevillageCorpscoldregionarestudiedinindoorthermalenvironment,providesthereferenceforthenextenergy-savingevaluationandenergy-savingdesign.BasedontheinvestigationofruralCorpsinseverecoldarea,thereferencestandard,guidelinerelated,todevelopruralenergysavingreformoftheexistinggreenbuildingevaluationmethod.Mainlyfromtheassessmentofthenecessaryconditions,assessmentprocedures,assessmentcriteria,assessmentmethods,assessmentandotheraspectsofthe.Analyzedtheenergysavingrenovationofexistingbuildingsenergy-savingpotential,economicandenvironmentalbenefitsofrelatedcalculationmethod,laidatheoreticalfoundationforlateranalysis.InastudentdormitorybuildinginShiheziareaastheobjectofstudy,lifecyclecostanalysismethodbasedonthemathematicalmodel,derivethewinterheating,summerairconditioningcostsandthecostofbuildingexteriorwallthermalinsulationmaterialtheinitialinvestmentcostandthethicknessofinsulationlayer,theoptimuminsulationthicknessdeterminethethicknessandthelowesttotalcostanalysiswithlimit,finalenergyconsumptionsimulationwiththeDeST-h,andthereconstructioneffectana
您可能关注的文档
- 变电站带电绝缘子干冰清洗机器人的研制研究-research and development of dry ice cleaning robot for live insulators in substations.docx
- 变电压下霍尔推力器放电特性的分析-analysis of hall thruster discharge characteristics under variable voltage.docx
- 变电站工程项目达标投产水平综合评价分析-comprehensive evaluation and analysis of compliance and commissioning level of substation project.docx
- 变电站高压设备发热故障智能检测系统的分析-analysis of intelligent detection system for substation high voltage equipment heating failure.docx
- 变电站集控智能告警系统分析-analysis of substation centralized control intelligent alarm system.docx
- 变电站间通信的多项目工程配置技术分析-analysis of multi-project engineering configuration technology for inter-substation communication.docx
- 变电站集中式广域后备保护算法分析-analysis of centralized wide area backup protection algorithm for substations.docx
- 变电站设备评估在巡视工作中的应用分析-application analysis of substation equipment evaluation in patrol work.docx
- 变电站接地网接地性能及其故障诊断成像系统分析-analysis of grounding performance of substation grounding grid and its fault diagnosis imaging system.docx
- 变电站现场通信网络架构及其关键技术分析-analysis of substation field communication network architecture and its key technologies.docx
原创力文档

文档评论(0)