三种体温测量方法在急诊预检分诊中应用分析

三种体温测量方法在急诊预检分诊中的应用分析   【摘要】 目的:比较三种不同体温测量方法,寻找适合于急诊预检分诊的快速和准确的电子体温计。方法:选择2014年11-12月到本院急诊科就诊的600例患者,于分诊时对各患者分别测量腋温、耳温和额温,并记录患者的一般资料。结果:三种体温测量方法中,腋温、耳温和额温的均值分别为(37.32±0.96)℃、(37.48±0.97)℃和(37.04±0.84)℃,三者间两两比较差异均有统计学意义(P0.05);腋温与耳温相比的差值为(-0.155±0.202)℃,95%一致性界限为(-0.551,0.241),在一致性界限内差值的绝对值最大为0.5 ℃;腋温与额温相比的差值为(0.284±0.448)℃,95%一致性界限为(-0.595,1.162),在一致性界限内差值的绝对值最大为1.1 ℃,耳温与额温相比的差值为(0.439±0.499)℃,95%一致性界限为(-0.539,1.417),在一致性界限内差值的绝对值最大为1.4 ℃。结论:耳温式电子体温计是可满足急诊预检分诊要求的快速、准确、安全的电子体温计。   【关键词】 体温; 测量方法; 急诊分诊   【Abstract】 Objective:To explore the fastest and most accurate body temperature measurement method in the emergency room through comparing three different measurements.Method:Recruited 600 patients visited our emergency room during November to December in 2014.All the patients’ body temperature were measured the following three different methods:temperature of forehead, of inner ear, and of axillary.Other general demographic characteristics were also recorded.Result:The mean values of these three temperature measures were (37.32±0.96)℃ of axillary,(37.48±0.97)℃ of inner ear and (37.04±0.84)℃ of forehead,with significantly differences between each other (P0.05).The difference value between axillary temperature and inner ear one was (-0.155±0.202)℃ with the 95% limits of agreement to be (-0.551,0.241) and the range in the limits to be 0.5 ℃. The difference value between axillary temperature and forehead ear one was (0.284±0.448)℃with the 95% limits of agreement to be (-0.595,1.162) and the range in the limits to be 1.1 ℃.The difference value between inner ear temperature and forehead one was (0.439±0.499) with the 95% limits of agreement to be (-0.539,1.417) and the range in the limits to be 1.4 ℃.Conclusion:It is the ear thermometer being satisfied with the need of fast,accurate,and safe for triage in the emergency room.   【Key words】 Body temperature; Thermometer; Emergency triage   First-author’s address:The Second Affiliated Hospital of Guangzhou Medical Univer

文档评论(0)

130****9768 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档