基于参数识别的线路保护的研究-电气工程专业论文.docxVIP

基于参数识别的线路保护的研究-电气工程专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Subject : Study of Transmission Line Protection Based on Parameter Identification Specialty : Electrical Engineering Name : Wang Xun (Signature) Instructor : Fu Zhouxing (Signature) Kong Xiangquan (Signature) ABSTRACT Traditional distance protection using fault time ratio of voltage and current, namely measuring impedance, characteristic of changes along with changes in voltage and current at the same time, judge or external fault in the region to achieve protection. For measuring impedance response the distance from the point of failure to protect the installation from non-electrical quantities, their protection from the influence of operation mode. But measuring impedance is the impedance angles contain resistance and reactance components, tuning very trouble. By analyzing the proposed protection algorithm of parameter identification of strengths and weaknesses, based on generalized algorithm for parameter identification of proposed protection method. Thesis research and analyse the principle and algorithm for two-Terminal fault location in frequency domain, in the Matlab double power supply model is built. Taking into account the basic requirements for line protection can be obtained through direct fault distance to determine whether the protection action, this algorithm is simple and easy tuning and so on. Considering coupling there is a complex of three-phase fault component, first the time domain signal is decoupled. Using a new type of phase-mode transformation, take advantage of the phase transformation of single modulus value response to all types of benefits, protection against influence of fault types. Secondly, in order to eliminate the non-truncated integer and non-periodic spectral leakage caused by sampling errors influence of fencing, on the analysis of the basic theory of the Fourier transform, principle and windowed interpolation algorithm based on studies interpolating windowed Fourier algorithm for correction of fractional frequency spec

您可能关注的文档

文档评论(0)

131****9843 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档