- 1、本文档共72页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
万方数据
万方数据
Subject :Research on Line-protection Including Distributed Energy
Generation
Specialty :PowerSystem and Automation
Name :Wang Yingli (Signature)
Instructor:Yun Baoji (Signature)
ABSTRACT
When distributed energy generation accessed to existing network, there will produce a negligible impacts such as power quality, line-loss, protection, etc. This research develops a line protection scheme containing distributed energy generation under the influence of distributed energy generation for the impact of distributed network relay protection. When the 10kV distributed network accesses to multiple distributed energy generation, the study select one of the case to research the impact on each part of the distribution network. This distributed energy generation divided original distribution network into three parts and need to develop different protection schemes for each part.
By analysis, a certain influence on the fault current after distributed energy generation accessed to distribution network and therefore corresponding two different protection operation setting should be set. O n the base of traditional three-current protection, this study makes appropriate adjustment on protection criterion for adjusting any kinds of fault. It is all known to us that traditional three-current protection will lose in some type of fault. Thus the study uses positive sequence, negative sequence and zero sequence of the fault current to form protection criterion. The criterion makes sure any faults have a certain protection range including two-phase short circuit.
At last, this research models 10kV distribution network simulation on PSCAD. After simulation analysis, the protection scheme will act on any types of fault.
Key words:Distributed Network, Distributed Energy Generation, Relay Protection, Traditional Three-current Protection, Criterion, PSCAD
Thesis :Applied Research
目录
目 录
HYPERLINK \l _bookmark0 1 绪论.........................................................
您可能关注的文档
- 固阳褐铁矿磁化焙烧小型工业化前期试验-矿业工程专业论文.docx
- 含金属芯压电陶瓷纤维的封装技术与性能研究-工程力学专业论文.docx
- 贵州中草药阔叶十大功劳化学成分及生物活性研究-农药学专业论文.docx
- 哈尔滨市年度土地供应计划研究-公共管理专业论文.docx
- 关于认知风格与大学生英语成绩关系的研究-课程与教学论(英语)专业论文.docx
- 韩国学生汉字教学调查与研究-对外汉语教学专业论文.docx
- 光场感应电离类钯氙X射线激光系统的等离子体特性研究物理电子学专业论文.docx
- 光解水制氢纳米催化剂的合成与优化研究-材料物理与化学专业论文.docx
- 果树挖坑定量施肥机的研制-机械设计及理论专业论文.docx
- 贵州傩戏面具艺术探究-艺术学专业论文.docx
文档评论(0)