火灾后型钢混凝土柱抗震性能及加固修复研究-结构工程专业论文.docxVIP

火灾后型钢混凝土柱抗震性能及加固修复研究-结构工程专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
万方数据 万方数据 宁波大学硕士学位论文 Study on seismic performance and strengthen of steel reinforced concrete columns after fire Abstract Fire would have a significant impact on the seismic performance of steel reinforced concrete column,Calculation of the remaining shear bearing capacity of steel reinforced concrete columns after fire has important significance to the fire damage evaluation and reinforcement of steel reinforced concrete column. But, the fire and seismic strengthening of concrete column steel repair research has not been reported related at home and abroad.A reasonable and feasible program was developed to research the seismic performance and restoration of steel reinforced concrete columns after fire.By being analyzed the failure mode failure mechanism,uctility, hysteretic behavior, energy dissipation capacity of steel reinforced concrete columns at room temperature and after fire. The test results show that: (1).The shear bearing capacity and stiffness were reduced after fire, Compared with the normal temperature specimens, the shear bearing capacity drop about 10% - 40%, the initial stiffness decreased about 25% - 37%; The ductility of the specimen was Increased to 1.05 times of the original. (2). The large shear span specimen(λ=2.5) was curved shear bond failure but no bending shear failure, The small shear span specimen(λ=1.5)was curved shear failure but no baroclinic shear damage. (3). Prestressing steel reinforcement has a great effect on specimens(λ=2.0, λ=1.5), Shear Capacity was improved 16.07% and 19.42% respectively compare to after fire,the ratio was 1.031,1.003 respectively compare to room temperature’s.The initial stiffness was improved 38.12%,21.71% respectively compare to after fire;it can be restored 88.21%,77.96% respectively to room temperature.But to specimens(λ=2.5),it’s has a low influence, the Shear Capacity was improved 13.6% to after fire,About 68.5% of room temperature’s; The initial stiffness was improved 4.26%,About 78.18% of room tempe

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档