  • 举报

Peak load reductions Electric load shifting with mechanical pre-cooling of residential buildings with low thermal mass 调峰:低热质住宅机械预冷电力负荷转移.pdf

Energy 82 (2015) 1057e1067 Contents lists available at ScienceDirect Energy journal homepage: /locate/energy Peak load reductions: Electric load shifting with mechanical pre-cooling of residential buildings with low thermal mass W.J.N. Turner a, b, *, I.S. Walker a, J. Roux a, c a Residential Building Systems, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA, USA b Electricity Research Centre, University College Dublin, Belfi eld Campus, Dublin 4, Ireland c INSA Lyon, 20 Avenue Albert Einstein, 69621 Villeurbanne Cedex, France a r t i c l e i n f o a b s t r a c t Article history: This study uses an advanced airflow, energy and humidity modelling tool to evaluate the potential for Received 23 October 2014 residential mechanical pre-cooling of building thermal mass to shift electricity loads away from the peak Received in revised form electricity demand period. The focus of this study is residential buildings with low thermal mass, such as 30 January 2015 timber-frame houses typical to the US. Simulations were performed for homes in 12 US DOE climate Accepted 4 February 2015 zones. The results show that the effectiveness of mechanical pre-cooling is highly dependent on climate Available online 26 February 2015 zone and the selected pre-cooling strategy. The expected energy trade-off between cooling peak energy sa