- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Different manufacturers use different calibration methods. Set by the manufacturer. This is mainly dependent on what method for producing dual energies is used. Scanners that use voltage switching (Hologic) need internal calibration. Scanners that use k-edge filters (GE-Lunar, Norland) need external calibration. Internal calibration works like this: Between the x-ray source and the patient, there is a calibration wheel (on newer system a drum). This wheel contains known amount of density (bone equivalent, air equivalent, and soft tissue equivalent). As the x-ray passes through the calibration beam, the x-ray source is continually calibrated to ensure stability of the the two energy peaks required for DXA. The practical side of this is that the technologist does not need to scan a calibration standard (different from phantom) daily. External calibration works like this: There is no calibration wheel between the x-ray source and the patient. Instead, each day the technologist must scan a calibration standard. This standard contains known amount of density (bone equivalent, air equivalent, and soft tissue equivalent). This ensures the stability of the the two energy peaks required for DXA. The practical side of this is that the technologist must scan the calibration standard (different from phantom) daily before scanning any patients. NOTE: Phantoms monitor the daily performance of your scanner: the phantom BMD value should remain stable over time. GE-Lunar aluminum phantoms (top). Water bath is soft tissue equiv. Norland (lower left) and Hologic (lower right) Hydroxyappatite phantoms. Phantoms are different from calibration standards. They do not ensure the stability of the dual energy beam. Instead they enable the center to monitor for shifts or drifts in the results (the causes are listed on the next two slides). Phantoms have a well-defined and narrow range of BMD values. For example, a phantom may have a range of BMD of 1.00 to 1.100. If the daily phanto
您可能关注的文档
最近下载
- (高清版)DB4401∕T 112.1-2021 《城市道路占道施工交通组织和安全措施设置 第1部分:交通安全设施设置》.pdf VIP
- 素食店创业计划书.pptx
- 5《秋天的怀念》—优质课课件(共30张PPT).pptx VIP
- 血管瘤治疗后护理.pptx
- 年产12000吨中药材中药饮片加工GMP项目可行性研究报告写作模板-备案审批.doc
- 有限空间作业考试试题库(附答案).docx
- 公共政策审计课件.pptx
- “分数除法”六年级上册第三单元整体教学设计.docx VIP
- 成考政治试题及答案.doc VIP
- 人教版七年级上册英语Starter Unit 3知识点梳理及语法讲义(学生版).pdf VIP
文档评论(0)