这是IEC-60950的空间和爬电距离要求.docxVIP

  • 54
  • 0
  • 约3.63千字
  • 约 3页
  • 2020-12-30 发布于山东
  • 举报
这是 IEC-60950 的空间和爬电距离要求: 附表 2J – AC 交流电源瞬间电压(摘录标准表 2J) AC main supply voltage up Mains transient voltage Vpeak b to and including a Overvoltage category Vr.m.s I II 50 330 550 100 500 800 150 c 800 1500 300 d 1500 2500 600 e 2500 4000 a For equipment designed to be connected to a three-phase, three-wire supply, where there is no neutral conductor, the AC MAINSSUPPLYvoltage is the line-to-line voltage. In all other cases, where there is a neutral conductor, it is the line-to-neutral voltage. The MAINS TRANSIENT VOLTAGE is always one of the values in the table. Interpolation is not permitt