冷弯卷边槽钢做楼板檩条时的间距取值.docx

冷弯卷边槽钢做楼板檩条时的间距取值.docx

楼板檩条C100X50X20X2.0在不同跨度、间距下的应力比 50mm厚楼板,恒载取 1.0kN/m2,活载取2.0 kN/m2 开间尺寸mm 间距600mm 间距900mm 间距1200mm 2100 0.379 0.518 0.678 2400 0.459 0.644 0.843 2700 0.549 0.785 1.031 3000 0.659 0.951 1.252 3300 0.779 1.134 1.496 3600 0.913 1.336 1.765 70mm厚楼板,恒载取 1.4kN/m2,活载取2.0 kN/m2 开间尺寸mm 间距600mm 间距900mm 间距1200mm 2100 0.413 0.569 0.747 2400 0.503 0.711 0.933 2700 0.606 0.870 1.145 3000 0.729 1.057 1.393 3300 0.865 1.264 1.667 3600 1.015 1.488 1.968 100mm厚楼板计算,恒载取 2.0kN/m2,活载取2.0 kN/m2 开间尺寸mm 间距600mm 间距900mm 间距1200mm 2100 0.454 0.646 0.850 2400 0.571 0.808 1.068 2700 0.691 0.995 1.316 3000 0.835 1.215 1.604 3300 0.995 1.455 3600 1.174 1.724 开间尺寸mm 间距600mm 间距900mm 间距1200mm 间距1500mm 3000 0.354 0.492 0.644 0.780 3300 0.409 0.576 0.757 1.294 3600 0.471 0.671 0.882 3900 0.540 0.774 1.020 4200 0.614 0.887 1.170 4500 0.685 0.995 4800 0.782(长细比不 足) 数据按70mm厚楼板计算,恒载取 1.4kN/m2,活载取2.0 kN/m2 开间尺寸mm 间距600mm 间距900mm 间距1200mm 3000 0.388 0.542 0.711 3300 0.450 0.637 0.838 3600 0.520 0.743 0.974 3900 0.596 0.860 1.134 4200 0.680 0.986 1303 4500 0.761 1.113 建议双梁 4800 0.868(长细比不足) 建议双梁 建议双梁 数据按100mm厚楼板计算,恒载取 2.0kN/m2,活载取2.0 kN/m2 开间尺寸mm 间距600mm 间距900mm 间距1200mm 3000 0.438 0.617 0.811 3300 0.497 0.728 0.960 3600 0.579 0.852 1.250 3900 0.688 0.987 1.305 4200 0.769 1.134 1.501 4500 0.874 建议双层梁 建议双层梁 4800 0.988(长细比不足) 建议双层梁 建议双层梁