楼板檩条C100X50X20X2.0在不同跨度、间距下的应力比
50mm厚楼板,恒载取 1.0kN/m2,活载取2.0 kN/m2
开间尺寸mm
间距600mm
间距900mm
间距1200mm
2100
0.379
0.518
0.678
2400
0.459
0.644
0.843
2700
0.549
0.785
1.031
3000
0.659
0.951
1.252
3300
0.779
1.134
1.496
3600
0.913
1.336
1.765
70mm厚楼板,恒载取 1.4kN/m2,活载取2.0 kN/m2
开间尺寸mm
间距600mm
间距900mm
间距1200mm
2100
0.413
0.569
0.747
2400
0.503
0.711
0.933
2700
0.606
0.870
1.145
3000
0.729
1.057
1.393
3300
0.865
1.264
1.667
3600
1.015
1.488
1.968
100mm厚楼板计算,恒载取 2.0kN/m2,活载取2.0 kN/m2
开间尺寸mm
间距600mm
间距900mm
间距1200mm
2100
0.454
0.646
0.850
2400
0.571
0.808
1.068
2700
0.691
0.995
1.316
3000
0.835
1.215
1.604
3300
0.995
1.455
3600
1.174
1.724
开间尺寸mm
间距600mm
间距900mm
间距1200mm
间距1500mm
3000
0.354
0.492
0.644
0.780
3300
0.409
0.576
0.757
1.294
3600
0.471
0.671
0.882
3900
0.540
0.774
1.020
4200
0.614
0.887
1.170
4500
0.685
0.995
4800
0.782(长细比不
足)
数据按70mm厚楼板计算,恒载取 1.4kN/m2,活载取2.0 kN/m2
开间尺寸mm
间距600mm
间距900mm
间距1200mm
3000
0.388
0.542
0.711
3300
0.450
0.637
0.838
3600
0.520
0.743
0.974
3900
0.596
0.860
1.134
4200
0.680
0.986
1303
4500
0.761
1.113
建议双梁
4800
0.868(长细比不足)
建议双梁
建议双梁
数据按100mm厚楼板计算,恒载取 2.0kN/m2,活载取2.0 kN/m2
开间尺寸mm
间距600mm
间距900mm
间距1200mm
3000
0.438
0.617
0.811
3300
0.497
0.728
0.960
3600
0.579
0.852
1.250
3900
0.688
0.987
1.305
4200
0.769
1.134
1.501
4500
0.874
建议双层梁
建议双层梁
4800
0.988(长细比不足)
建议双层梁
建议双层梁
原创力文档

文档评论(0)