QC-034 样品测试报告 Rev.0.docVIP

  • 9
  • 0
  • 约1.09千字
  • 约 1页
  • 2021-02-10 发布于广东
  • 举报
PAGE 1 - APPENDIX F SAMPLE TEST REPORT CUSTOMER XELITE P/N MODEL NO. CUSTOMER P/N Items No. Test Items Unit Test condition result Spec. Limit Pass/Fail 90Vac 60Hz 115Vac 60Hz 230Vac 50Hz 264Vac 50Hz 1 Unload input current mA — 2 Unload input power W — 3 Rated load input current mA ≤ mA 4 Rated load input power W — 5 Unload output voltage (0.0A) V Vdc 6 Rated load output voltage ( A) V Vdc 7 Rated load Output ripplenoise voltage ( A) mV ≤ mVp-p 8 Short-circuittest (PinIout) W ≤6W 9 Over current protection A OCP≤ A 10 Output overshoot % ≤10% 11 Turn on delay time mS ≤3000mS 12 Hold up time mS ≥10mS /(115Vac) ≥20mS /(230Vac) 13 Efficiency % ≥ % 14 Hi-pot test Pri. to Sec. : 4242Vdc, 1Minute, Cut off current≤10mA (Test result: 0.0002mA) 15 Max. and Light load change test Max. load to Light load:OK   Light load to max. load: OK (90-264Vac) 16 Burn-in Burn-in 4 Hrs, The sample OK 17 Appe. label and fusion Appearance: OK, Label: OK, Fusion: OK XELITE P/N REV. DATE ISSUED BY CHECKED BY APPROVED BY QC-034/A

文档评论(0)

1亿VIP精品文档

相关文档