PrimePACKTM Parallel Connection CONTENTS Page 1 Current imbalance at steady state 2 2 Current imbalance at switching 5 3 Gate drive circuit 6 4 Wiring example for parallel connections 7 PrimePACKTM is registered trademark of Infineon Technologies AG, Germany. This document explains the notes when PrimePACKTM IGBT module is connected in parallel. IGBTs would be connected in parallel in order to enlarge the current capability. In this case, the number of parallel-connected modules has no limitation. However you have to consider some disadvantages of noise or spike voltage increase, which are caused by longer interconnections. You have to pay attention to the following basic notes when connecting IGBT modules in parallel. 1) Suppression of current imbalance at steady states 2) Suppression of current imbalance at dynamic state of turn-on or turn-on 1 MT5F28605 Parallel Connection for PrimePACKTM 1 Current imbalance at steady state An on-state current imbalance is caused mainly by the following two factors: (1) VCE(sat) distribution (2) Main circuit wiring resistance distribution 1.1 Current imbalance caused by V distribution CE(sa