- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Gas flow, however, generates concerns about possible thermal shielding and/or buoyancy effects. Thermal shielding can be understood from Figure 10.22. Gas flow downward to the sample holder will make the holder shield the thermocouple junction from convective heat transfer through the flowing gas. Consequently, the thermocouple junction temperature will not be the same as for a sample with flowing gas. The buoyancy (浮力) effect is illustrated in Figure 10.24. Gas flow upward will generate a lifting force on the sample holder. This effect is similar to weight loss of a sample body in liquid. Such gas flow effects are difficult to eliminate. Careful calibration and good instrument design reduce such problems to a minimum. * When the Curie point of a ferromagnetic sample is reached, the magnetic downward force disappears and weight loss will be recorded in the TA curve The fusible line method can also be used as a calibration temperature. A fusible wire with known melting temperature connects the microbalance suspension wire and inert mass pieces. The fusible wire should locate the position of sample in the furnace. Melting of the wire at its melting temperature causes mass loss, which is recorded in the TG curve. * The heating rate affects TG curves considerably, similar to DTA and DSC. For example, with endothermic decomposition, a high heating rate will increase the starting and finishing temperatures of decomposition. Also, the temperature range from start to finish will be wider at a higher heating rate than a lower heating rate. Figure 10.26 shows an example of the effect of heating rate on the TG curve of polyvinyl chloride (PVC). There are two reasons for heating rate effects. First, high heating rate is more likely to generate a temperature difference between the sample and thermocouple junction. The real sample temperature may lag behind that of the thermocouple. Second, in decomposition with volatile products, it takes time for those products to diffuse out o
您可能关注的文档
- 光学课件:第5章-光的偏振-4.ppt
- 光学课件:光的偏振复习.ppt
- 光学课件:光学复习1.ppt
- 光学课件:光学复习2.ppt
- 激光原理学课件:Chapter 0-2-1 经典物理学的辉煌与新现象的发现.ppt
- 激光原理学课件:Chapter 0-2-3 玻尔的氢原子理论.ppt
- 激光原理学课件:Chapter 0-2-5 波函数与薛定谔方程.ppt
- 激光原理学课件:Chapter 1Introductory Concepts.ppt
- 激光原理学课件:Chapter 2 Interaction of Radiation with Atoms and Ions.ppt
- 激光原理学课件:Chapter 3 Energy Levels, Radiative, and Nonradiative Transitions in Molecules and Semiconductors.ppt
原创力文档


文档评论(0)