网站大量收购独家精品文档,联系QQ:2885784924

Pulse mode shear horizontal-surface acoustic wave (SH-SAW) system for liquid based sensing applications》.pdf

Pulse mode shear horizontal-surface acoustic wave (SH-SAW) system for liquid based sensing applications》.pdf

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Pulse mode shear horizontal-surface acoustic wave (SH-SAW) system for liquid based sensing applications》.pdf

Biosensors and Bioelectronics 19 (2004) 627–632 Pulse mode shear horizontal-surface acoustic wave (SH-SAW) system for liquid based sensing applications Fabrice Martin a , Michael I. Newton a,∗, Glen McHale a , Kathryn A. Melzak b , Electra Gizelib a School of Science, The Nottingham Trent University, Clifton Lane, Nottingham NG11 8NS, UK b Institute of Biotechnology, University of Cambridge, Tennis Court Road, Cambridge CB2 1QT, UK Received 30 October 2002; received in revised form 27 June 2003; accepted 9 July 2003 Abstract In this work, we describe a novel pulse mode shear horizontal-surface acoustic wave (SH-SAW) polymer coated biosensor that monitors rapid changes in both amplitude and phase. The SH-SAW sensors were fabricated on 36◦ rotated Y-cut X propagating lithium tantalate (36 YX.LT). The sensitivity of the device to both mass loading and visco-elastic effects may be increased by using a thin guiding layer of cross-linked polymer. Two acoustic modes are excited by the electrodes in this crystalline direction. Metallisation of the propagation path of the 36 YX.LT devices allows the two modes to be discriminated. Successive polymer coatings resulted in the observation of resonant conditions in both modes as the layer thickness was increased. Using the 36 YX.LT devices, we have investigated the application of a novel pulse mode system by sensing a sequence of deposition and removal of a biological layer consisting of vesicles of the phospholipid POPC. A continuous wave system was used to verify the accuracy of the pulse mode system by sensing a series of poly(ethylene glycol) (PEG) solutions. The data clearly demonstrates the ability of the 36 YX.LT pulse mode system to provide rapid measurements of both amplitude and phase fo

您可能关注的文档

文档评论(0)

ycwf + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档