- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
基于纳米金和硫堇固定酶 的过氧化氢生物传感器 答辩人:陈贤光(03应化) 指导老师:童叶翔 教授 邹小勇 教授2006.6 广州 Hydrogen Peroxide Biosensor Based on Immobilizing Enzyme by Gold Nanoparticles and Thionine① CHEN, Xian-Guang ZOU, Xiao-Yong TONG, Ye-Xiang*School of Chemistry and Chemical Engineering, Sun Yat-Sen University, Guangzhou 510275, China ① This paper will submit to Acta Chim. Sinica . 1. Introduction1.1 Mechanism of Hydrogen Peroxide Biosensor Guilbault G. G. , et. al. Anal. Chim. Acta. , 1973, 64: 439-445. 1. Introduction 1.2 Fabrication of hydrogen peroxide biosensor made in our work 1. Introduction 1.3 Catalytic reaction of H2O2 appear in the system 2. Results and Discussion 2.1 Prepare GNs by sol-gel method Fig. 1 TEM image of GNs. ( d = 20 nm ) 2. Results and Discussion 2.2 Electrochemical impedance spectrum (EIS) Fig. 2 Nyquist plot of EIS of the electrodes (a) and equivalent circuit (b) of the biosensor. (a) (b) Rapp : electrode apparent resistance; Rsol : solution resistance; Rct : charge transfer resistance. Electrode Rapp / Ω Rsol / Ω Rct / Ω a 1179 9326 1724 b 2208 9623 6334 c 3536 9882 3780 d 5016 144.6 7580 Table 1 Electrochemistry parameters 2. Results and Discussion 2.3 Atomic force microscopy (AFM) images Fig. 3 Three-dimensional AFM images of bare Pt (a), Pt/GNs (b), Pt/GNs/Thio (c) and Pt/GNs/Thio/(HRP-GNs) (d) electrode. 2. Results and Discussion 2.4 Cyclic voltammgrams (CVs) (b) Fig. 5 CVs of electrocatalysis of the biosensor to H2O2 in pH 7.0 PBS containing 1×10-3 mol/L hydroquinone. (a) Fig. 4 CVs (a) of the biosensor at different scan rates in blank pH 7.0 PBS and the linear calibration curve between scan rates and cathode peak currents (b). 2. Results and Discussion 2.5 Some factors effect on the response currents Fig. 6 Effect of applied potential on the response currents of the biosensor to 2×10-4 mol/L H2O2. Other conditions
您可能关注的文档
最近下载
- 全国第七届中小学音乐优质课比赛教学设计 跳圆舞曲小猫.pdf VIP
- 复合材料力学(全套课件).ppt VIP
- 社会支持评定量SSRS.pptx VIP
- 不良资产处置培训.pptx VIP
- 项目风险评估报告模板范例(标准版).docx
- 13-肿瘤基因组学.pptx VIP
- (正式版)D-L∕ T 646-2012 输变电钢管结构制造技术条件.docx VIP
- 外研版(2019)选择性必修 第四册Unit4 Everyday economics Using language 课件(共20张PPT).pptx VIP
- SL 72-2013水利建设项目经济评价规范.doc VIP
- JISB1181_螺母.pdf VIP
文档评论(0)