网站大量收购独家精品文档,联系QQ:2885784924

《Label-free aptamer biosensor for thrombin detection based on functionalized graphene nanocomposites》.ppt

《Label-free aptamer biosensor for thrombin detection based on functionalized graphene nanocomposites》.ppt

  1. 1、本文档共16页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Reporter: Chongkun Wang Date:2015.12.10 Email:xldlx_liqun@139.com Literature Reports 东华理工大学化学生物与材料科学学院 Faculty of Biology, Chemistry and Material Science, East China University of Technology Label-free aptamer biosensor for thrombin detection based on functionalized graphene nanocomposites (Chongkun Wang. Talanta. 2015) College of Chemistry, Jilin University IF 3.545 Content Background 1 Experimental 2 Results and Discussions 3 Conclusion 4 Background thrombin(TB) detection sensitivity and selectivity electrochemical impedimetric aptasensor EIS Rct essential for diagnosis thrombosis and hemostasis Apparatus and Chemicals Experimental Zahner Zennium electrochemical workstation for EIS CH Instrument 832B electrochemical workstation for CV three electrode electrochemical cell: Ag–AgCl reference electrode,a bare gold working electrode, a platinum wire electrode. JEM-2100F high-resolution transmission electron microscope,HITACHIH-600 Analytical TEM, ESCALAB-MKII spectrometer (VG Co., United Kingdom) Graphene oxide(GO) 、Dithiothreitol(DTT)、Tris(2carbo-xyethyl) phosphine hydrochloride(TCEP)、Rhodamine6G (R6G)、Chlor-oauric acid(HAuCl4 .4H2O)、Tris(hydroxym-ethyl) aminomethane(Tris) Thiolated thrombin aptamers TBA15(5′-HS-SH-(CH2)6-TTT TTT TTG GTT GGT GTG GTT GG-3′) and TBA29(5′-HS-(CH2)6-TTT TTT TTA GTC CGT GGT AGG GCA GGT TGG GGT GAC T) Thrombin,bovine serum albumin(BSA), Trypsin, immunog-lobulinG (IgG) was prepared in 34mM Tris HCl methanol and store at 4℃ rGO–AuNPs: 60mg of sodium citrate was added to homogeneous GO dispersion under refluxing and stirring(2.5h);100μL HAuCl4 was added to the above solution and reflux(30min);rGO–AuNPs dispersion was centrifuged at 12,000 rpm and washed with water and redispersed into 6mL water by sonication. rGO–TBA29: 20μL of TCEPand excess of TBA29 was added to100μL rGO–AuNPs suspension and ediluting to 0.5mL with water in 24h; twice centrifugation at 12,000 rpm for 10min and then add 100μL of 0.1mM R6G. electrode modific

文档评论(0)

1318384917 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档