Electrical Condition Survey Procedures and Forms for Buildings ELECTRICAL CONDITION SURVEY FOR BUILDINGS How to Conduct an Electrical Condition Survey PURPOSE: To systematically investigate the condition and adequacy of the electrical power distribution system in any building or structure for compliance with good engineering design practice and National Electrical Code. EQUIPMENT REQUIRED: NEC National Electrical Code 1999 Digital Multimeter: Fluke 8060A Clamp-on Current Probe: Fluke I80 Insulated Screw Driver Flash Light Micrometer 0-1 Outlet Tester Daniel Woodhead 1750 or 1756 GFI Tester 15 Kohm Resistor in 3-Prong Plug Ground loop impedance tester Ground Check Model 7100 ECOS Electronics Corp. Wire Gauge Light Meter GE 213 or attachment for fluke Tape Measure Condition Survey Form Blank Panel Directory 1 phase and 3 phase PROCEDURE: Start at transformer, KVA size is usually printed on side of transformer. Record this. Obtain impedance for Short Circuit Calculation from power company. (R, X, Z, and Primary Short Circuit KVA if available). R = resistance, X = reactance, Z = impedance Is metering Utility Company on the side of the building or subfed from Forest Service owned distribution system? Check one. Is service drop aerial or underground, size: AWG or MCM, type: copper (CU), or aluminum (AL.), insulation type: RHH, RHW, THW, non. Length of service from transformer to building. Is there a main switch or circuit breaker on side of building or on meter distribution pole? If so, size, accessibility good, bad? What is system voltage, phase, wire? Most common: 120/240 Volt, 1 phase, 3 wire; 120/240 Volt, 3 phase, 4 wire, Delta; 120/208 Volt, 3 phase, 4 wire, Wye; 277/480 Volt, 3 phase, 4 wire, Wye. Wire size: Usually printed on insulation, if not, measure insulation diameter, with micrometer then go to NEC Table 5, 753 of insulation to find wire size under proper insulation type. If circuit is de-energized, actual wire diameter may be meas

文档评论(0)

heti94575 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档