高层建筑嵌固端(Embedded end of high-rise building).docVIP

高层建筑嵌固端(Embedded end of high-rise building).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
高层建筑嵌固端(Embedded end of high-rise building)

高层建筑嵌固端(Embedded end of high-rise building) Thanks to the steel structure forum wxl_1973 Abstract: the structure of the high-rise building block to determine the fixed end has a great influence on the authenticity and accuracy of the calculation results of the structure, so the correct selection of structural fixed ends and the structure of fabric reinforcement structure and give the necessary protection, is an important link in structure design. In this paper, the choice of embedded end of high-rise building structure is discussed, and some related problems that deserve to be considered and solved are pointed out. 1. introduction The high-rise building must first determine the structure of fixed end position before the structure analysis and calculation, and the selection of built-in end faces different situations, such as no basement foundation but deeply buried; without a basement, but the number of more or less, and different foundation forms etc.. According to the above correct selection of the structure of fixed end is calculated, the high-rise building structure model is an important assumption, it is not only related to the accuracy of distribution of some component internal force in the structure, but also affect the structure of the authenticity of the lateral displacement, and the economy of the local structure, so it is necessary to further explore the block structure the fixed end of the selected, and byextension, some related technical problems. The condition of the embedded end of the structure The embedded end of high-rise building is usually chosen to be marked on the ground, but the ground elevation is conditional on the embedded end of the structure, and there is a lot of attention when calculating the height of the first floor. 2.1 the condition of having a basement (1) the basement roof elevation and outdoor floor height can not be too large, extreme conditions such as semi basement is the first floor can be structural fixed ends, unless its hei

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档