折减选择、振型个数(Reduction selection, mode number)

折减选择、振型个数(Reduction selection, mode number) Condition: 1. set the live load allowance in the PMCAD menu, and the load transmitted to the beam is reduced and the load on the wall is not reduced (2010 edition, PMCAD manual, p74). The live load reduction in 2.satwe provides only the options for column walls and foundations. 3. load gauge bar 4.1.2. Live load input 4. upper structure in the program according to the standard of floor reduction coefficient of load transfer to the foundation did not affect the value, if we consider the load reduction by floor should be considered in the JCCAD program (the 2010 edition of the jccad manual P37). Suppose: A, if the selection is reduced in PMCAD, the SATWE does not select, then the beam design meets the requirements of the standard 4.1.2-1 strong bar, and the wall column foundation does not meet the requirements of the 4.1.2-2 strong bar. 4.1.2-1, if the selection is not reduced in PMCAD, the design of the beam does not meet the requirements of SATWE, and the wall column foundation meets the requirements of 4.1.2-2 strong bar B. C, if the selection is reduced in PMCAD, the SATWE is also chosen to be reduced, the beam wall design meets the requirements, and the column live load is reduced by two times (2010 edition, PMCAD manual, p74). Results: the calculation of a wall column is too large, and the standard value of conduction to the foundation will be reduced. Select the B beam to calculate too large. The choice of C column is too small and the calculation is too small. Recommendation: do not choose to discount in pacad, select discount in SATWE, violate strong strip 4.1.2-1, but secure The live load passed to the foundation in SATWE, the allowance and the non reduction option do not affect the foundation design ************************************************************************************************************************** Seismic code specification 5.2.2: the number of vibration modes can generally take vibration mo

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档