文献翻译-10Ω中性点接地电阻对利比亚西部30KV电网的影响.docVIP

文献翻译-10Ω中性点接地电阻对利比亚西部30KV电网的影响.doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
10 ohm Neutral Grounding Resistance in 30kV Western Libyan Network and Effects Eng. Hasan Z. Al-Amari Ministry of Electricity and Renewable Energy, Libya hasan_zawam@ Dr. Abdallah I. Fadel University of Tripoli, Libya fadel.abdalla@ Abstract- Direct Grounding of the transformer neutral point leads to single line to ground fault current with a high-value, which may reach the value of the three-phase fault current or more.This high fault current causes destruction of fault locations (equipments and operators), and raises the ground voltage that increases the high step and touch voltages, which is dangerous to humans and animals, causes destruction of communications equipment and can be of great danger to the users.Those high fault currents can be reduced by inserting resistance to the neutral point of injection feeding transformer. In this research, the importance and effect of neutral grounding resistance in 30kV system network and its impact in the determining and limiting of the single line to ground fault currents for a network fed by a single or multi sources will be addressed.Also, the characteristics of the neutral grounding resistance installed in 220/30 kV transformer will be determined and discussed. According to the historical data, two events of tripping happened in 30kV transformer substation in Tripoli area network, due to high single line to ground fault. The behavior of single line to ground fault current for the above mentioned tripping events in Tripoli area were measured, and this will be compared to the simulated results of the same cases and discussed. The ATP (Alternative Transient Program) and Neplan software programs are used for simulation of such events [5] [6]. Finally, the effect of the Temporary Over Voltage (TOV), which is also called Power Frequency Over Voltage, on the healthy phases during the single line to ground fault current occurs will be discussed, as well as the effect of the neutral grounding point. Key Words- Neutr

您可能关注的文档

文档评论(0)

***** + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档