- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Zeta电位实时在线测定方法与监测系统-检测技术与自动化装置专业论文
II
II
REAL-TIME AND ONLINE MEASUREMENT METHOD OF ZETA POTENTIAL AND MONITORING SYSTEM
ABSTRACT
Coagulation is a commonly used method for wastewater treatment,and the essence is to remove charged colloidal particles and suspended solids, the key technology is precisely controlling the amount of flocculant.The effect of coagulant is to change the electrical properties of solid-liquid interface,while zeta potential is the potential of slip surface which is in the colloidal structure of the electric double layer.The greater of the zeta potential, the stability of colloid is much butter.Because flocculants can compress the electrical double layer , zeta potential decreases then elimination the stability of colloid and coagulation. The samller of the zeta potential, the better of effect of flocculation.Therefore, not only can zeta potential characterize flocculation effect, also can accurately guide flocculant dosage.
Against the measuring equipments of zeta potential are almost offline, different batches of wastewater and zeta potential, the optimum flocculant dosage is different. To accurately obtain the optimum dosage of flocculant,this paper presents a method of measuring the zeta potential online which can real-time measure the zeta potential of wastewater.Using the phenomenon of interface electrokinetic, measure the flow potential value within the capillary channel structure, and according to Helmholtz-Smoluchowski equation, indirectly get the zeta potential of wastewater.The experiment data shows that within the allowable error,the zeta potential could real-time guide flocculant dosing.While exploring the conditions of water quality and the effects of operating conditions on the measurement results, it?s propel to get the stirring speed, PH value and pressure conditions,which minimizes the measurement error. In addition, using neural network model can establish the curve
III
III
of flocculant quantity and zeta potential, the curve can accurately pr
您可能关注的文档
- XHD科技公司研发人员流失原因及对策研究-工商管理专业论文.docx
- XHH五金制品有限公司转型升级的分析-工商管理专业论文.docx
- XHS公司的劳动关系管理诊断与对策-工商管理专业论文.docx
- XHYL集团ERP实施中项目人力资源管理的研究-工商管理专业论文.docx
- XH公司企业文化建设效果评价及改进研究-企业组织与战略管理专业论文.docx
- XH公司发展战略分析-工商管理专业论文.docx
- XH公司发展战略研究-工商管理专业论文.docx
- XH公司发展战略研究工商管理专业论文.docx
- XH公司销售管理型CRM系统构建研究工商管理专业论文.docx
- XH置业公司多项目管理信息系统设计与开发-软件工程专业论文.docx
- ZFA公司产权制度和治理结构方案研究工商管理专业论文.docx
- ZFP580在ROS介导的心肌细胞氧化应激损 伤中的作用-心血管内科专业论文.docx
- Zfy基因干扰对小鼠性别控制的研究-基础兽医学专业论文.docx
- ZF汽车零部件企业供应链管理策略的探讨-工商管理专业论文.docx
- ZGHN集团公司湖南分公司发展战略优化研究-工商管理专业论文.docx
- ZGN国有银行温州分行绩效管理体系研究-工商管理专业论文.docx
- ZGPA保险公司品牌营销策略研究-工商管理专业论文.docx
- ZGS公司财务风险管理研究-工商管理专业论文.docx
- ZGYD无线音乐俱乐部品牌定位与传播策略研究-工商管理专业论文.docx
- ZGZHLPJ集成原型系统中多形态模块集成接口技术-计算机技术专业论文.docx
文档评论(0)