VICKERS®
Directional Controls
DG3V-7, 20 Series, Pilot Operated
DG5V-7, 40 Series, Solenoid Controlled, Pilot Operated
ISO 4401 Size 07
Typical Section Basic Characteristics
Mounting . . . . . . . . . . . Surface mounting
DG5V-7-2C Spring-Centered Valve Example Max. pressure . . . . . . 350 bar (5000 psi)
Max. flow . . . . . . 300 L/min (80 USgpm)
General Description Features and Benefits
Models include spring offset, spring
DG*V-7 valves are used primarily for centered, pressure centered and High pressure and flow capability for
controlling the starting, stopping and detented versions. All are available with maximum cost-effectiveness.
direction of fluid flow. the option of an integral P-port pilot Low headloss to minimize power
pressure generator. DG5V valves can wastage.
Two series of valves, DG5V solenoid
be arranged for internal or external pilot Low shock characteristics to
controlled, pilot operated and DG3V pilot
pressure and/or drain connections. maximize machine life.
operated models are available with a
Facility to change solenoid coils
choice of 18 different spools. These