安装规律档距L(m)电线型号UJ-25单位

核温度3540454950556065707580859095100105110115120直径6.45mm

审(℃)规律档距下的弧垂f(m)综合截面25.41mm²

本-400.050.070.080.100.110.140.170.220.280.350.440.560.710.891.101.331.591.862.15最高载流允许温度+70℃

卫-350.060.070.090.110.120.150.190.240.310.390.500.630.800.991.211.451.711.982.26最大设计应力53.7846N/mm²

何-300.060.080.100.120.130.160.210.270.350.440.560.710.891.091.321.561.822.092.38安全系数3

对-250.070.090.110.140.140.180.240.300.390.500.640.800.991.201.431.681.932.202.49弹性系数59000N/mm²

校-200.080.100.130.150.160.210.270.350.450.570.720.901.101.311.541.782.042.312.60线膨胀系数0.0000231/C

-150.090.110.140.170.180.240.310.400.520.650.821.001.201.421.651.892.152.422.70使用气象区注3

-100.100.130.170.200.210.270.360.460.590.740.911.101.301.521.752.002.252.522.80

伦-50.120.150.190.230.240.320.420.530.670.541.011.201.401.621.852.102.452.622.90

00.140.190.230.270.280.370.480.610.760.921.101.301.501.721.952.192.352.723.00

50.180.230.280.320.340.440.560.700.851.021.201.391.601.812.052.292.552.813.09注:

100.220.270.330.390.400.510.640.780.941.101.291.481.691.912.142.382.642.913.191、观测档弧垂

150.270.330.400.450.470.590.720.861.021.191.371.571.782.002.232.472.733.003.28式中:Lx-观测弧垂档的档距(m).

200.330.390.460.520.54.0.660.800.941.101.271.461.651.862.082.322.562.823.083.36f一规律档距下的弧垂(m).