网站大量收购独家精品文档,联系QQ:2885784924

第十四章 管道系统的设计(The fourteenth chapter is the design of piping system).doc

第十四章 管道系统的设计(The fourteenth chapter is the design of piping system).doc

  1. 1、本文档共7页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
第十四章 管道系统的设计(The fourteenth chapter is the design of piping system) The 0304 contribution by Peng Chuyun PPT document may at the WAP end of the browsing experience poor. Suggest you select TXT, or download the source file to the machine view. The fourteenth chapter The design of piping system In chapter 1. the design principles of piping layout principle 1. piping 2. pipeline calculation pipeline design 2. A pipeline layout principle 1. general principles: General principles: simple, compact structure, convenient operation and maintenance, no dirt, simple and compact structure, convenient operation and maintenance, no fouling, wear less 2. pipeline erection requirements should be vertical or inclined to erect, inclined angle pipe (1) should be vertical or inclined erection, inclined pipeline angle (angle and the horizontal plane) should not be less than the rest angle. 35 angle) should not be less than the rest angle. The general 350-550 for level set up, also should be as short as possible, for the level of erection, should be as short as possible, there must be enough wind speed as little as possible turn radius as large as possible, 2) as little as possible turn radius as large as possible, the minimum diameter of 1 times the size of 1-2 3) branch pipe and the horizontal or inclined head connected from top or side access, three way pipe angle should generally not be less than 30 access, an angle of three pipe should not be generally less than 300, the maximum should not exceed 450 Piping layout principle 4) tapered tube and diffuser diffusion angle less than 150 tapered tube and diffuser diffusion angle of less than 155) pipeline and beam, column, wall, there is enough pipeline and beam, between the equipment and pipe distance, to meet the requirements of construction, operation, maintenance and expansion and contraction General requirements. Distance to meet the requirements of construction, operation, maintenance and expansion requirements. The spacing of not l

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档