施工图审查中常犯的错误(Often make mistakes in the construction plan review)
施工图审查中常犯的错误(Often make mistakes in the construction plan review)
Often make mistakes in the construction plan review posts has been viewed 818 times | reply 27 times
Mistakes often made in the examination of construction drawings!
Mistakes often made in the examination of construction drawings!!!
1., fire elevator room and other rooms between the partition door hole, no fire gate.
2., the fire zone at the entrance of the underground garage is not equipped with a fire prevention door, and the use of air defense doors instead of fire doors. (Z, I dont know yet.)
3. underground garage access closed staircase, door is not set B fire door.
4. there is no fire shutter at the entrance and exit of the ramp.
5. after the basement is equipped with sprinkler system, a fire area is still over 1000 square meters. (non garage use)
6. underground garage, fire area of more than 500 square meters
No fire gate has been set up between the 7. diesel generator room and the oil storage room, and no measures to prevent oil dispersion have been taken.
(the above reason is the specification specified by the provisions of the contents of a, B and C fire door is not familiar with)
8. the door should not be opened directly to the staircase.
9. the direction of the fire door opens towards the deformation joint.
10. staircase elevator combined atria window opening area less than 3 square meters, does not meet the high.
11. double staircase and public stair guardrail used cross railing; teaching platform, staircase, balcony, low window
Choose the form of railings easy to climb, does not meet the specifications.
12. is not familiar with the provisions of the special buildings, the design is not in place (such as sports, construction, etc.).
13. bedroom, kitchen upper for the toilet, no water, sound insulation and easy to repair measures.
14. glass area of more than 1.5 square meters, in the door and window instructions that the use of safety glass.
15. above the kitchen window opening should be se
您可能关注的文档
- 影响产业结构的因素及论文选题(The influence factors of industrial structure and the topic).doc
- 影响混凝土强度的因素(The influence factors of concrete strength).doc
- 影响审计因素及改善(Influence factors and improvement of audit).doc
- 影视制作中的多声道数字立体声录音(Multi channel digital stereo recordings in film and television production).doc
- 影响音频质量的几种重要的参数(Effects of several important parameters of audio quality).doc
- 影响物流中心选址因素(The factors that influence the location of logistics center).doc
- 影响马铃薯生长的外界环境(Environmental influence on the growth of potato).doc
- 影视论文(Film paper).doc
- 影评《活着》张艺谋(The alive Zhang Yimou).doc
- 往届安全员考试(The previous safety examination).doc
- 施工安全检查表(Construction safety check list).doc
- 施工基础知识要点(The construction of basic knowledge points).doc
- 施工安全汇编目录(Construction safety assembly directory).doc
- 施工必须看(The construction must see).doc
- 施工总平面布置(The general layout of construction).doc
- 施工实习个人总结(The construction of personal practice summary).doc
- 施工图设计制图基本规则(The basic rules of construction drawing design drawing).doc
- 施工技术答案(The construction technology of the answer).doc
- 施工工艺大全大型悬挑现浇钢筋混凝土异形柱施工技术(The construction technology of the large cantilever cast-in-place reinforced concrete special-shaped column construction technology).doc
- 施工组织与进度控制(The construction organization and schedule control).doc
文档评论(0)