新时达系统常见故障分析(Common fault analysis of new system)

新时达系统常见故障分析(Common fault analysis of new system) Common fault analysis of new system The 32 step analysis system in elevator fault First, the reasons for not open the door when the overhaul: 1, the F64 parameter is not set to 1; 2, open door area signal is not (F130 = 0, as long as there is a flat switch action, there should be gate area signal; F130 = 1, there must be independent gate switch input); 3, you can open the floor settings parameters wrong; 4, open limit signal error (input point normally open / normally closed setting error, switch or wiring error); 5, the door button signal is not received. Two, the maintenance can not be closed: 1, the F64 parameter is not set to 1; 2 、 error of closing limit signal (input point normally open / normal setting error, switch or wiring error); 3, safety touch plate switch action or input point normally open / stop setting error; 4, the closing button or up and down button signals are not received. Three, when the door can be closed, but not automatically closed (even press the closing button) reasons: 1 overload switch action or the input point normally open / stop setting error; 2 communication failures between the motherboard and the car board; 3, if the software version number is 01F3TV053 and the updated version, there may be no driver: the elevator is in full or a driver bypass state, the operation of the elevator car in front of the instruction signal is not registered; 4, driver or independent state, no command and call signal registration, so the elevator does not run direction; 5, no driver status, open the door button often action; 6, F163 is set to have a function extension board, but it doesnt actually feature the extensions board (01F3TV053 and newer versions); 7, seismic detection of function expansion board, building emergency power supply detection, or power failure emergency flat level device operation detection input point misoperation (01F3TV053 and updated version); 8, if the elevator is Schindler, th

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档