- 1、本文档共91页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
人工髋点关节假体力传递与假体近端骨整合机理研究-机械制造及其自动化专业毕业论文
摘要制造出定制式人工髋关节假体,在提高假体与髓腔匹配度的同时,减小股骨近端
摘要
制造出定制式人工髋关节假体,在提高假体与髓腔匹配度的同时,减小股骨近端 的应力遮蔽。进行定制式假体的力传递有限元仿真,与标准式假体的力传递进行 比较,得出结论。 关键词:人工髋关节假体;三维模型重建;有限元分析;力传递分析;骨整合
万方数据
AbstractAbstract
Abstract
Abstract
with the aging of Chinese society progresses,the amount of total hip replacement surgery presented an increasing trend.
Total hip replacement surgery using hip prosthesis replace the lesions hip prosthesis,prosthesis assembl at one end of the femoral canal,and the other end connected to the acetabulum.The main factors of artificial hip prosthesis failure is osseointegration and stress shielding,straight stem prosthesis and distal canal leads to a lower degree of matching,which may cause the prosthesis aseptic loosening.
Force artificial hip prosthesis of stress shielding,and other issues、)vitll aseptic loosening of the prosthesis transfer characteristics are closely related.When the force
on the prosthesis call not be transmitted to the proximal femur,proximal femur will
produce osteolysis,unable to make the prosthesis and the femur form a good
integration,lack of stability of the prosthesis in the canal,tends to cause no prosthesis bacteria loose.When the prosthesis and medullary cavity match、析tll a low degree of matching form,the force on the prosthesis to the proximal femur transfer,easy to damage the proximal end of the prosthesis osseointegration area,the impact of long—term stability ofthe prosthesis in the medullary cavity,also leads to false body in canal sterile loose.To improve the long-term stability of the prosthesis in the medullary cavity of the need to establish fmite element model of the prosthesis in the
medullary cavity and with experimental,in·depth study of the geometric parameters of the prosthesis,the relationship between form and false match between the physical transfer in raising false under the premise of matching body and the canal,the control
force is transmitted to the prosthesis on the proximal femur,proximal promote
osseointegration of the pr
您可能关注的文档
- 气液共进料的高通量固定床反应器的研究和在催化反应中的应用发-工业催化专业毕业论文.pdf.docx
- 汽车轻等量化技术(学员版)三.ppt
- 汽车等速万向节周期循环试验台关键技术的研究-机械三制造及其自动化专业毕业论文.pdf.docx
- 气相色谱质谱联用技术对水产品中激素多残留检测的研究-水产品加工与中贮藏工程专业毕业论文.pdf.docx
- 汽车高速碰撞下防撞结构的优化设计研究-车辆工程专业毕业论的文.pdf.docx
- 汽车零部件新产品开发项目风险管理应用研究等项目管理专业毕业论文.pdf.docx
- 气体超声波时流量计系统数学模型建立与信号处理方法研究-检测技术与自动化装置专业毕业论文.pdf.docx
- 墙地砖施对工工艺.ppt
- 墙柱面装饰分项工程量计点算规则.ppt
- 嵌入式系统开条发基础.ppt
- 2-红河州建筑施工安全生产标准化工地复核评分表(2022年修改版).docx
- 6.锡通项目2018年下半年工作会汇报材料(2018.7.9).docx
- 2018道路工程知识点汇总(新版).docx
- 附件3:月度生产例会安全汇报资料-站台门项目部.docx
- 附件2:广东建工集团2018年度科技成果汇总表.DOC
- 马武停车区、三汇停车区停车位管理系统,0#台账缺量.doc
- 攀成钢委办发〔2015〕19号(党风廉政建设责任考核与追究办法).doc
- 1-红河州建筑工程质量管理标准化复核评分表(2022年修改版).docx
- 中交第三公路工程局第四工程分公司项目经济合同结算管理办法(修订).doc
- 厂站安全操作规程汇编.doc
文档评论(0)