Abstract
Abstract
In electrostatic precipitator, the current state is very complex body movement, turbulent
structure, collection of the dust collector of fine dust impact is very large, and so, improve
precipitator internal current body motion is essential. In this paper, in the form of plates from
collecting dust in change, we devised a way shaped plate that is on the discharge electrodes on
both sides of the plate are perforated, to reduce dust in the ion wind speed, objective to
improve dust collection rate of fine dust.
First of all, according to the experimental parameters, create 2D simplified model
precipitator, ambit software is used to divide the discharge space. close to the discharge
2
electric field intensity change is very dramatic, so close to the discharge electrode 100mm
range pave mesh refinement, in an amount of 3 times the external grid, then the different
forms of the grid were designed other ranges grid solutions, and for comparison. Finally
established the optimum mesh solution.
Secondly, use software to simulate the discharge space fluent fluids. Traditional plates
were shaped plates and dust inside the ion wind speed contrast at the same voltage, wind
speed of 0.6m/s, contour contrast velocity vector, wind speed at different voltages
corresponding to different values of the velocity profile comparison, shaped plate than the
original plates obtained fine dust collection rate of conclusion, and measured the actual test
results match.
Finally, five electrodes under simulated conditions inside the precipitator i
您可能关注的文档
最近下载
- 固定资产管理培训.pptx VIP
- SONY索尼数码录音笔PCM-A10使用说明书.pdf VIP
- AfterEffects动态图形与动效设计(全彩慕课版)PPT全套完整教学课件.pptx
- 30 万吨年 双氧水法环氧丙烷装置及配套 90 万吨年双氧水装置项目环评.pdf
- 2024年中考数学复习:综合题几何类比探究题型(含答案与解析).pdf VIP
- 国际法知到课后答案智慧树章节测试答案2025年春上海财经大学.docx VIP
- 偏轮抽油机设计-毕业(学术)论文设计.doc VIP
- 恶性肿瘤PPT课件.ppt
- 公司关键岗位人员因私出国(境)管理规定.docx VIP
- Manual_RTC4_english(RTC4激光打标卡手册,英文).pdf VIP
文档评论(0)