基于DR成像系统的锥束CT成像研究-生物医学工程专业论文.docxVIP

基于DR成像系统的锥束CT成像研究-生物医学工程专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ABSTRACT Digital Radiography (DR) imaging equipment has been widely used in clinical practice and gradually spread to the primary medical institutions in our country. Accurate performance assessment of DR imaging equipment is the prerequisite to ensure its rational clinical application, so it has important application value. The International Electrotechnical Commission adopted modulation transfer function(MTF) for performance evaluation of DR imaging equipment, and recommended knife-edge method as one of the MTF measurement method. Knife-edge method has advantages in accurately obtaining the low-frequency characteristics of MTF, but the error in tilt angle measurement of the knife-edge object prevents accurate MTF estimation in high frequencies. This problem has become one of the major concerns in this research area around the world. A novel method for precise MTF measurement based on interpolation floating technique was proposed in this paper. By investigating the quantitative relationship among the interpolation floating value, the variation of the line spread function (LSF), and the attenuation characteristics of the MTF curves in the presence of noise, we demonstrated that the tilt angle measurement error caused the interpolation number deviation from the ideal benchmark interpolation and resulted in worse smoothness of the LSF curves and higher attenuation level of the MTF curves than the actual one. The MTF measurement error due to the edge angle measurement error was effectively relieved by using the interpolation floating method. This method has great application value because it reduced the tough requirements in high-precision angle measurement of MTF estimation According to the cone-beam CT imaging theory and the performance evaluation results of the DR system, a multi-dimensional and semi-automatic cone-beam imaging platform was built for three-dimensional imaging of small animals. The calibration phantom was designed for the calibration of the cone-bea

您可能关注的文档

文档评论(0)

131****9843 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档