食品分析(英文课件):GAS CHROMATOGRAPHY.pptVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Methods Conditions which can be varied to accommodate a required analysis include: the columns stationary phase, diameter and length inlet temperature detector temperature column temperature and temperature program carrier gas and carrier gas flow rates inlet type and flow rates sample size injection technique chromatographic condition operating conditions separation condition: column Flow rate of carrier gas Column temperature Condition of sample injection Detector The selection of chromatographic column The main chemical attribute regarded when choosing a column is the polarity of the mixture. The polarity of the sample must closely match the polarity of the column stationary phase to increase resolution and separation while reducing run time. The separation and run time also depends on the film thickness (of the stationary phase), the column diameter and the column length. Tavella et al detection of TFA in 46 popular Argentina foods column: CP Sil 88 (50m×0.25mm) Supelco Omegawax 250(30m ×0.25 mm,0.1μm) chromatographic condition: inlet temperature: 250℃, FID: 250℃, column temperature: 185℃(3min)-3℃/min-230℃,M.P. He,column pressure: 19 psi, split ratio: 1:70 Results film thickness (of the stationary phase), the column diameter and the column length e.g.60m × 0.25 mm, 0.2μm length: Increase the column length is good for separation of mixture, but the retention time increased accordingly. 15m:rapid detection simple analyte 25~30m:most commonly used overlength(50、60、100m):complex compound The selection of chromatographic column Column diameter small diameter: analysis speed Resolution , but column capacity easier to be overload Increase diameter: column efficiency 0.15mm/0.22mm/0.25mm -split sample injection 0.32mm/0.53mm Thickness 0.25~0.5μm, Most widely used Thick film:Retention time Thin film: Temperature Retention time , suitable for high boiling point, thermal-sensitive compounds Column Slection Pretreatment of new column o

文档评论(0)

学习让人进步 + 关注
实名认证
文档贡献者

活到老,学到老!知识无价!

1亿VIP精品文档

相关文档