Quality Control as a part from Quality Assurance 质量控制是质量保证的一部分

Prepared by :FDR Prepared by :FDR * Quality Control Rad T 110 * Aim : The purpose of QC to achieve high quality images with the least amount of radiation. Quality Control is a part of Quality Assurance program * Test Types: Acceptance test Monitoring test Annual Test After repair or tube replacement * Acceptance Test: Performed upon newly installed equipment to verify purchase specification and to establish performance base line. Frequency: To be performed once only when new machine is installed * Monitoring Test: Performed for vital parameter on routine basis. Frequency: Every 2-3 months * Annual Test: Performed for vital parameter Frequency: once a year * Parameters to be checked Beam Alignment and Collimator Accuracy Radiation output and linearity of mR/mAs versus kV (Large and small FS Assessment of Total Beam Filtration (HVL) Assessment of Focal Spot size Accuracy and constancy of Exposure Timer Measuring of Scattered Radiation (using Water Phantom) Leakage Radiation from X-Ray tube 1-5 Monitoring test, 2- Annual Test * Parameters to be checked 1. Beam Alignment and Collimator Accuracy Beam Alignment Test Tool Small hole * Parameters to be checked 1. Beam Alignment and Collimator Accuracy X-ray Tube Test Tool * 1. Beam Alignment and Collimator Accuracy Improper central ray alignment will distort a radiographic image. When used with the Collimator Test Tool, this device provides a simple means of determining if the X-ray beam is perpendicular to the image receptor and centered with respect to the light field. * 1. Beam Alignment and Collimator Accuracy * Parameters to be checked 2. Constancy of Radiation output and linearity of mR/mAs versus kV2 (Small Large focus) Victoreen Kv Meter Displays kVp maximum, kVp average, kVp effective, dose and time * Parameters to be checked Constancy of Radiation output and linearity of mR/mAs versus kV2 (Small Large focus) Set mAs=20 for LF 10 for SF X-ray Tube Table top Measure kVp Output * Radiati

您可能关注的文档

文档评论(0)

118books + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档