Rapid sterilization of medical devices for orthopedic equipment sterilization Effect.doc

Rapid sterilization of medical devices for orthopedic equipment sterilization Effect.doc

  1. 1、本文档共17页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Rapid sterilization of medical devices for orthopedic equipment sterilization Effect

 PAGE \* MERGEFORMAT 17 Rapid sterilization of medical devices for orthopedic equipment sterilization Effect Qualitative sterilization test method to detect fast-YN-A type of medical sterilizer sterilizing effect of orthopedic devices. A result, when the sterilizer chamber temperature to 210 ℃ , 220 ℃ , 230 ℃ , 240 ℃ and 250 ℃ , respectively, of the re-100g, 210g, 320g, 560g and 800g infected Bacillus subtilis var of orthopedic devices the role of 8min can achieve sterilization effect; test equipment weight and achieve the sterilization chamber set temperature was positively correlated. The rapid sterilization of medical device sterilization required by the ambient temperature rose to the highest temperature (270 ℃ ) about the time required for 3min. Conclusion, rapid sterilization of medical devices to the small amount of orthopedic devices in the sterilization temperature of 210 ~ 250 ℃ to maintain sterilization 8min, can achieve sterilization requirements. Sterilizer, rapid sterilization, orthopedics, equipment Hospitals to carry out orthopedic surgery, often because of intraoperative situation is complex, ill-prepared sterile surgical instruments, for some special equipment needed emergency sterilization, under the conditions of military hospitals, especially in the field. Because of orthopedic apparatus bulky shapes, Sterilization and high demand, sterilized using conventional sterilization methods difficult to meet the requirements of an emergency. To this end, we earned Connaught Medical Equipment Co., Ltd. developed the YN-A type of medical rapid sterilizer (hereinafter amp;quot;medical rapid sterilizeramp;quot;). To verify that the actual emergency medical rapid sterilizer sterilizing effect, in the military hospital operating room sterilization effect of its application observed. Now report on the results as follows. A method 1.1 sterilizer sterilizer for medical rapid cavity volume of 300mm * 500mm * 240mm, cavity, the lower containing respe

文档评论(0)

hhuiws1482 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:5024214302000003

1亿VIP精品文档

相关文档