Rapid sterilization of medical devices for orthopedic equipment sterilization Effect
PAGE \* MERGEFORMAT 17
Rapid sterilization of medical devices for orthopedic equipment sterilization Effect
Qualitative sterilization test method to detect fast-YN-A type of medical sterilizer sterilizing effect of orthopedic devices. A result, when the sterilizer chamber temperature to 210 ℃ , 220 ℃ , 230 ℃ , 240 ℃ and 250 ℃ , respectively, of the re-100g, 210g, 320g, 560g and 800g infected Bacillus subtilis var of orthopedic devices the role of 8min can achieve sterilization effect; test equipment weight and achieve the sterilization chamber set temperature was positively correlated. The rapid sterilization of medical device sterilization required by the ambient temperature rose to the highest temperature (270 ℃ ) about the time required for 3min. Conclusion, rapid sterilization of medical devices to the small amount of orthopedic devices in the sterilization temperature of 210 ~ 250 ℃ to maintain sterilization 8min, can achieve sterilization requirements.
Sterilizer, rapid sterilization, orthopedics, equipment
Hospitals to carry out orthopedic surgery, often because of intraoperative situation is complex, ill-prepared sterile surgical instruments, for some special equipment needed emergency sterilization, under the conditions of military hospitals, especially in the field. Because of orthopedic apparatus bulky shapes, Sterilization and high demand, sterilized using conventional sterilization methods difficult to meet the requirements of an emergency. To this end, we earned Connaught Medical Equipment Co., Ltd. developed the YN-A type of medical rapid sterilizer (hereinafter amp;quot;medical rapid sterilizeramp;quot;). To verify that the actual emergency medical rapid sterilizer sterilizing effect, in the military hospital operating room sterilization effect of its application observed. Now report on the results as follows.
A method
1.1 sterilizer sterilizer for medical rapid cavity volume of 300mm * 500mm * 240mm, cavity, the lower containing respe
您可能关注的文档
- Quality Standard of nourishing sedative pills.doc
- Quality standard of Qingfei Oral Liquid.doc
- Quality standard of thistle_0.doc
- Quality Standard of Tianqi.doc
- Quality Standards Bazhen Yimu Pills Research.doc
- Quality standard of thistle.doc
- Quality Standard compound of Sophora_0.doc
- Quality Standard Zhibai Dihuang Wan.doc
- Quality standards of the tablet pain of disease.doc
- Quality Standards spur Capsules.doc
文档评论(0)