网站大量收购独家精品文档,联系QQ:2885784924

电扇装置(Fan device).doc

  1. 1、本文档共9页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
电扇装置(Fan device) 1. The function and design requirements of the device desktop fan shook his head. The working principle and technological process of 1.2 1.1 working principle of functional decomposition electric fan is the fan air supply area of the cyclical change, achieve the goal of increasing supply area. Obviously, in order to complete the swing of the electric fan, the following motor function requirements should be realized: (1) the fan needs to be swayed by the movement rules, so the corresponding oscillating mechanism should be designed. (2) the fan needs to change the transmission axis and change the rotational speed, so the corresponding gear mechanism should be designed. Motor function of the two institutions for further analysis, know they should achieve the following basic movement respectively: (3) the swinging has three basic movement: movement axis transformation, transmission ratio and periodic oscillation. (4) there is a basic movement of the axis of movement and the change of the transmission ratio: the axis of motion. Also, meet the requirements of transmission performance: change the fan air supply area, the back swing Angle coefficient K = 1.02, the request of the phi 90 °, try to keep a smooth transition and reduce the friction between the institutions. The original data and design requirements 1.3.1 the original data fan diameter was phi 300mm, the motor speed of the electric fan was 1450r/min, and the fan shook the head period T = 10s. Swing Angle fan Ψ = 90 ° and back coefficient k = 1.02. 1.3.2 the design requires that the shaking of the shaking device of a desktop electric fan be designed to swing with a given emergency coefficient and swing Angle to achieve a combined movement of the rotation of the fan blade and the movement of the shaking head. 1.4 design task, page 3, 12 pages of jiangxi agricultural university mechanical principles curriculum design 1. 2. Drawing organization movement schematic diagram. 3. Assign worm gear and gear

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档