西安市天然气加气站建设规范(Code for construction of natural gas fueling station in Xian).docVIP

西安市天然气加气站建设规范(Code for construction of natural gas fueling station in Xian).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
西安市天然气加气站建设规范(Code for construction of natural gas fueling station in Xian)

西安市天然气加气站建设规范(Code for construction of natural gas fueling station in Xian) The metering device shall comply with the following requirements: (1) measurement accuracy should not be lower than 1; (2) the measurement shows that the corresponding minimum division value is 1Nm3 in Nm3 (3) when measuring the volume value, a temperature sensor shall be attached. After correction, the reading value shall be converted to the standard state. 4.4 desulfurization and dehydration of natural gas When 4.4.1 enters the gas station, the hydrogen sulfide content of the gas station is greater than 20 mg / m3, and the desulfurization device shall be installed in the station. 4.4.2 natural gas dehydration unit should be located in front of compressor. 4.5 compression of natural gas 4.5.1 the buffer tank can be set as needed before the compressor. The volume of the buffer tank shall be calculated at the natural gas residence time of not less than 10s. The buffer tank shall be provided with a filter device, the tank top is provided with a safety valve, and the opening pressure of the safety valve is 0.95-1.0 times of the maximum inlet pressure value of the compressor. 4.5.2 into the compressor of natural gas dust, diameter less than SY / T7514 1, 88 standard filter device should be added. 4.5.3 pipe flow rate: compressor front main pipe is not greater than 20m / S; compressor rear main pipe is not greater than 5m/s. The selection of 4.5.4 natural gas compressor shall be determined in accordance with the design scale of the fueling station, the volume of the on-board vehicle in the station gas storage station and the fueling station. Compressor is usually switched on 12 16h per day. 4.5.5 compressor inlet and outlet pipes, valves and accessories shall comply with the following requirements: (1) manual valves and solenoid valves shall be provided for imported pipelines; (2) the outlet pipe shall be provided with manual valves, check valves and safety valves. The opening of the safety valve

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档