快速成型个体化导航模板辅助胸椎椎弓根螺钉置入可行性探究.docVIP

快速成型个体化导航模板辅助胸椎椎弓根螺钉置入可行性探究.doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
快速成型个体化导航模板辅助胸椎椎弓根螺钉置入可行性探究

快速成型个体化导航模板辅助胸椎椎弓根螺钉置入可行性探究   作者:陈玉兵 陆声 徐永清 张元智 师继红 陈国平 【摘要】 :[目的]通过尸体标本实验的方法探讨个体化导航模板辅助胸椎椎弓根螺钉置入的准确性及可行性。[方法]对6具胸椎尸体标本进行CT扫描,根据CT扫描资料,利用逆向工程原理及快速成型技术设计制造出个体化导航模板,利用个体化导航模板在尸体标本上辅助置入胸椎椎弓根螺钉,所有螺钉的置入由同一位具有腰椎椎弓根螺钉置钉经验但无胸椎椎弓根螺钉置钉经验的骨科医师进行操作,随后采用大体解剖的方法肉眼观察置钉的准确性;并根据螺钉是否穿破椎弓根、穿出距离及穿破方向进行分级。[结果]共设计制作了72个个体化导航模板辅助置入胸椎椎弓根螺钉144枚,132枚(91.7%)螺钉完全在椎弓根内;12(8.3%)枚螺钉穿破椎弓根,其中2枚螺钉穿破椎弓根内侧壁(穿破距离分别为0.6、0.8 mm),10枚螺钉穿破椎弓根外侧壁(9枚螺钉穿出距离lt;2 mm,1枚螺钉穿出距离为2.5 mm);没有椎弓根上方、下方及椎体前方穿破的螺钉。所有穿破椎弓根壁的螺钉均在安全可接受的范围内。[结论]快速成型个体化导航模板辅助胸椎椎弓根螺钉置入准确率高,对术者无特别的经验要求,手术操作简单、安全,可避免术中放射性损伤,为胸椎椎弓根螺钉的置入提供了一种新的可行方法,尤其适用于初学者。 【关键词】 胸椎 椎弓根螺钉 快速成型 逆向工程 个体化导航模板   Abstract:[Objective]To validate the accuracy and feasibility of transpedicular screw placement assisted by individual navigation templates in the thoracic spines by a cadaveric study.[Method]A novel individual navigation template was developed by reverse engineering and rapid prototyping according to preoperative CT data of six thoracic cadavers.The templates were used for thoracic pedicle screw placement in the cadavers.All screws were implanted by an experienced orthopaedic surgeon in the lumbar spines but not in the thoracic spines.Subsequently,an anatomic dissections were performed to evaluate the accuracy of the placed screw and orientation relative to the pedicle axis.The relative position of the screw to the pedicle was graded.[Result]Totally 144 pedicle screws assisted by 72 individual navigation templates were implanted in the cadaveric thoracic spines.Totally 132(91.7%) screws were completely inserted within the pedicle.Twelve(8.3%) screws breached the pedicle cortex,which included 2 medial and 10 lateral breaches.Two medial breaches were respectively 0.6 mm and 0.8 mm distance from pedicle cortex,and 9 lateral breaches were less than 2 mm and the other one were 2.5 mm.No screw breaches were superior or inferior to the pedicle,or anterior to the vertebral body.All misplaced screws were within an acceptable range.[Conclusion]Transpedicular screw plac

文档评论(0)

docman126 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:7042123103000003

1亿VIP精品文档

相关文档