- 4
- 0
- 约1.35万字
- 约 13页
- 2019-03-06 发布于江苏
- 举报
Standard: EN61558-1:1997+A1+A11 EN61558-2-6:1997
Page PAGE 1/ NUMPAGES 13
FOY TIME \@ M/d/yyyy 6/23/2008
Engineer
WXQ
Client:
Lab Engineer
Appliance:
AC / DC transformer
Requested Date
26/
Model No.
MKD41 DC Series
Expected Date:
Sample No.
Report No.
SAP No. + Item
Full test
FORMCHECKBOX
Retest
FORMCHECKBOX
Lab Measurements return to Engineer directly
FORMCHECKBOX (If no tick, put into default tray)
Lab Use Only
Lab Start Date
/
Lab Finish Date
/
FORMCHECKBOX For modification / retest, changes from last model: ______________________________________________
Product technical data
Power inlet class
Direct plug-in
IP index
IP4X
Mobility
Portable
Time of operation
Continue
Intended use
Independent
Short-circuit proof
Fail-safe
Rated Supply Voltage
FORMTEXT 230V~
Rated Supply Frequency
FORMTEXT 50Hz/60Hz
Rated Output Voltage
See model list
Rated Output Current
See model list
Rated Ambient temperature
25 °C
Test item
Clause
Description
Clause
Description
11
Measuring output
18.3
Dielectric strength
12
Measuring no-load output
18.4
High frequency
14.2
Heating
19.15
Strain on socket-outlet
15
Abnormal
20.9
Protective device
16.2
Impact
27.1
Ball-pressure for enclosure
16.4
Tumbling, turn torque and pull
27.2
Glow-wire for enclosure
17.2
Humidity
27.4
Ball-pressure glow-wire
18.2
Insulation resistance
Date Signature Date Signature Date Signature
Test Engineer Check by Approved by
Note: Clause 11.1 and 12 tested when steady state reached, So measured immediately after 14.2 heating test.
11.1(d)
O/P Voltage and output current under load
Test
Supply Voltage
230V
Model
Rated O/P
Load Impedance
(Ω)
Measured O/P Voltage
Deviation
230V
230V
MKD41-0600500
6VDC, 500mA
12
MKD41-0600600
6VDC, 600mA
10
MKD41-0600800
6VDC,800mA
7.5
MKD41-0601000
6VDC,1000mA
6
Remark
Deviation must less than 10%
12
No-load output voltage
Test
Supply Voltage
230V
Model
Output
(VA)
Measure
原创力文档

文档评论(0)