CONTENTS 1. INTRODUCTION:2 2. PROFIBUS: GENERAL CHARACTERISTICS:3 3. GENERAL PRODUCT SPECIFICATIONS4 3.1. REMIO PROFIBUS Interface characteristics:4 4. INSTALLATION:5 4.1. Address setting:5 4.2. Connections:6 4.2.1. Connections on basic module:6 4.2.1.1. Profibus connector:6 5. PROFIBUS USER INFORMATION7 5.1. Principle: Data Transfer description / State Diagram7 5.2. Slave diagnostic:9 5.2.1. Description of diag bytes in the first part of the diag field:9 5.2.2. Description of diag bytes in the second part of the diag field: (user diag field): command word10 5.3. Configuration:11 5.4. Parametrisation:13 5.5. Global control:13 5.6. Access to the DI/DO ports and TPO channels:14 5.6.1. Digital input/output (DI/DO) Ports:14 5.6.2. Time proportioning outputs (TPO):15 5.7. Other services:15 6. PERFORMANCES:16 7. TROUBLE SHOOTING:17 7.1. Profibus status LEDs (basic module):17 7.2. Input / Output status LEDs:18 7.2.1. Digital Input /Output modules (DI/DO modules):18 7.2.2. Time Proportioning Output module (TPO modules):18 8. DEVICE DATA BASE (DDB):19  REMIO : PROFIBUS-DP Communications Interface Communications Manual Part N° HA 176078 ENG - Issue 2.0 - 07/2000 1. INTRODUCTION: This manual describes Profibus communications implementation in REMIO/TPO and REMIO/Digital (DI/DO) TE series interfaces. Concerning any detail about these units or their functionnal operation, please refer to: - HA175874ENG iss.2 manual for REMIO/TPO interface - HA175726ENG iss.2.0 manual for REMIO/Digital (DI/DO) interface. Fo