WorleyParsons 沃利帕森斯设计指南 KS-PR-DEG-0130 Line Sizing Design Guide.pdf

WorleyParsons 沃利帕森斯设计指南 KS-PR-DEG-0130 Line Sizing Design Guide.pdf

Line Sizing DesignGuide Document No: KS-PR-DEG-0130 Rev 0 01 December 2019 © Copyright 2019 Worley ACN 096 090 158. No part of this document or the information it contains may be reproduced or transmitted in any form or by any means electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, withou t permission in writing from Worley. Table of Contents 1. Introduction 4 2. Scope 4 3. Line Sizing – General 4 4. Hydra Introduction 6 4.1 Hydra 6 4.1.1 Hydra Limitations 6 4.2 Commercial Programs 6 5. Input Required 6 5.1 Normal Operating Cases 7 5.2 Maximum Operating Flow 7 5.3 Special Operating Cases 7 6. Phasing of Line Sizing 7 6.1 Conceptual Design Study 7 6.2 Basic Design and Engineering (FEED) Project 7 6.2.1 Tentative Line Sizing 7 6.2.2 Tentative Definition of Hardware 8 6.3 Detailed Engineering Project 9 7. General Line Sizing Topics 10 7.1 Preferred Diameters 13 7.2 Pipe Roughness 13 7.3 Fouling 13 7.4 Noise 14 7.5 Erosional Velocity 14 7.6 Vibration Induced Fatigue Failure 16 7.6.1 Line Sizing and Flow Induced Vibration 17 7.6.2 Acoustic Induced Vibration 21 Line Sizing Design Guide ii KS-PR-DEG-0130 Rev 0 01 December 2019 7.7 Static Electricity Generation 21 7.8 Pressure Drop Across Equipment 22 7.9 Flow Range and Pressure Drop of Flow Meters 25 7.10 Pressure Drop of Control Valves 26 7.11 Pressure Drop and Flow Range of Check V