变电站高压隔离开关自动控制技术的研究机械工程专业论文

哈尔滨工业大学工程硕士学位论文 哈尔滨工业大学工程硕士学位论文 - - II - Abstract Studying the way of high-voltage disconnector interlocking and the high- voltage disconnector control system, this paper described the interlocking strategy of 500kV substation secondary system, the high-voltage disconnector control system and monitoring system automated principle in detail. This paper analyzed the substation automation system, the high-voltage disconnector automation system, the interlocking way and control principle. It presented the high-voltage disconnector auto-control system improved method. It discussed the applicability and the rationality. This paper analyzed the interlocking way and the high-voltage disconnector control circuit with the Liaoyang 500kV substation as the example. By building the logic block diagram of interlocking and the logic interlocking model, made the control interlocking relation of the bus disconnector, the line disconnector and the branch disconnector more limpid, made the logic interlocking more perfect. By analyzing contradiction between the interlocking program and electrical interlocking, modified and perfected the oriental interlock relation. So the Computer-Based interlocking relation adapts the field operation more. This paper thorough studied the computerized monitoring system of the high-voltage disconnector with the system of Liaoyang 500kV substation as the example. By the means of the accuracy test of the computer measure and control device, it approved the disconnector auto-control system feasibility and reliability. By the means of the high-voltage disconnector inspection state analysis, it designd the switchover circuit of inspection state and reduces the mistake operation accident of manual releasing the interlocking. By the means of the high-voltage disconnector accident analysis, it designed the diagnose circuit of high-voltage disconnector, improve the capability of high-voltage disconnector accident check, supply the protective to extrahigh voltage

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档