基于双端电气量距离保护耐受过渡电阻性能改善的研究-电力系统及其自动化专业论文.docxVIP

基于双端电气量距离保护耐受过渡电阻性能改善的研究-电力系统及其自动化专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Subject :The Research of Improving the Ability to Withstand Fault Resistance in Distance Protection Based on Double Terminals Specialty :Power System and Automation Name :Cheng Qiutao (Signature) Instructor:Yun Baoji Liu Jian (Signature) ABSTRACT Distance protection is one of important means for fault handing on transmission line. But fault resistance is an important factor to influence the distance protection performance. The opposite terminal is easy to obtain in smart grid. Based on the original input on distance protection, using the opposite terminal can improve the ability to withstand fault resistance in distance protection. This paper firstly summaries the research of the current situation on transmission line protection, then proposes a new principle to improve the ability to withstand in distance protection which based on double terminal’s electrical information, aiming to solve the problems of the traditional distance protection caused by the exist of the change of transition resistance. The paper is based on 1 mode equivalent circuit of transmission line, derive a ranging equation for protection in a particular frequency according to the characteristic of equal voltage of the point of failure.Then expands the functions of hyperbolic sine and cosine into the Taylor series in equation of distance protection. Then Ignore polynomial of high order to approximate in three methods, we can get three kinds of ranging equations for protection, using least square optimization algorithm to obtain the fault distance. Finally, the most suitable algorithm can be determined by comparing estimation accuracy of the fault distance under the three algorithms and considering the amount of computation algorithms. The Taylor series expansion and simplified calculation is the innovation of this paper. In order to actualize the improvement of protection performance using the principle which is proposed, we need to filtered the information of the specific frequency componen

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档