毛细管电泳技术在玉米代谢组学中的应用研究-工业催化材料表征技术专业毕业论文.docxVIP

毛细管电泳技术在玉米代谢组学中的应用研究-工业催化材料表征技术专业毕业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
IV IV Abstract Capillary electrophoresis (CE) has been applied in many fields owing to its advantages of high separation efficiency and fast speed. However, the detection sensitivity of CE is greatly limited due to the small injection volume and the short optical path length. Currently, in order to improve the detection sensitivity of CE, various sample concentration methods have been investigated and developed. The metabolites of corns were analyzed by CE coupled with on-line concentration methods. The major content is described as follows: Two on-line concentration methods, namely field-enhanced sample stacking and dynamic pH junction, were utilized to improve the detection sensitivity. When field-enhanced sample stacking method was used, nine water-soluble vitamins were focused and separated baseline. When dynamic pH junction method was used, only nicotinic acid and folic acid were focused. The limits of detection of the vitamins were from 6 to 119 ng/mL (2.7×10-8 to 53.4 ×10-8 M) based on the signal-to-noise ratio of 3 and the relative standard deviations of migration time and peak area for each vitamin (1 μg/mL) were less than 3.5% using the field-enhanced sample stacking as an on-line concentration method. The developed method was applied to the analysis of water-soluble vitamins in corns and two vitamins, pyridoxine hydrochloride and nicotinic acid, were detected. The estimated concentration of them were 2.5 ± 0.11 μg/g - 6.67 ± 0.17 μg/g and 0.25 ± 0.01 μg/g - 0.67 ± 0.08 μg/g respectively. The recoveries of them were 87 %-106 % and RSDs were less than 6.81%. Two on-line concentration methods, namely field-enhanced sample stacking and dynamic pH junction, were utilized to improve the detection sensitivity. Seven purine bases and pyrimidine bases were focused and separated baseline using two methods. Comparing to field-enhanced sample stacking, dynamic pH junction was more suitable for the concentration of purine bases and pyrimidine bases since the sensitivi

您可能关注的文档

文档评论(0)

131****9843 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档